{"id":26286,"date":"2025-06-10T15:05:06","date_gmt":"2025-06-10T15:05:06","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=26286"},"modified":"2025-06-10T15:05:11","modified_gmt":"2025-06-10T15:05:11","slug":"c3425-c4751i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3425-c4751i","title":{"rendered":"C3425 (C4751i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Trouble type<\/td><td>C3425: Fusing warm-up trouble<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up.The temperature detected by the heating roller temperature sensor (TEMS) does not shift from the pre-standby state even after the lapse of a predetermined period of time after the completion of warm-up.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>Fusing unitHeating roller temperature sensor (TEMS)DC power supply (DCPS)CPU board (CPUB)Base board (BASEB)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Check the fusing unit for correct installation (whether it is secured in position).<\/li>\n\n\n\n<li>Check the open\/close operation of the right door.<\/li>\n\n\n\n<li>Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check CPUB for proper installation and correct as necessary.<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/6351365899.html\">Replace the fusing unit.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/7408636555.html\">Replace CPUB.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/7408577675.html\">Replace BASEB.<\/a><\/li>\n\n\n\n<li>DCPS\u00a0F102 or FU181\u00a0conduction check.<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/15273301643.html\">Replace DCPS.<\/a><\/li>\n<\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/15400068875.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C3425: Fusing warm-up trouble Rank A Trouble detection condition Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up.The temperature detected by the heating roller temperature sensor (TEMS) does not shift from &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3425-c4751i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3425 (C4751i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":227,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1394],"epkb_post_type_1_tag":[],"class_list":["post-26286","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-4750i-4050i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26286","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/227"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=26286"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26286\/revisions"}],"predecessor-version":[{"id":26288,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26286\/revisions\/26288"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=26286"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=26286"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=26286"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}