{"id":26341,"date":"2025-06-10T17:15:34","date_gmt":"2025-06-10T17:15:34","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=26341"},"modified":"2025-06-10T17:15:39","modified_gmt":"2025-06-10T17:15:39","slug":"c6753-c4751i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6753-c4751i","title":{"rendered":"C6753 (C4751i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Trouble type<\/td><td>C6753: ASIC clock input error (back side)<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>When starting the machine, verification on reading and writing the predetermined value for CPU (image processing section) on CPU board (CPUB) was conducted, and verification failure was detected.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>DF CIS module (DF CIS)CPU board (CPUB)Base board (BASEB)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Check the connector between DF CIS-BASEB CN5 for proper connection and correct as necessary.<\/li>\n\n\n\n<li>Check CPUB for proper installation and correct as necessary.<\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/7470481931.html\">Replace the DF CIS module assy.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/7408636555.html\">Replace CPUB.<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/7408577675.html\">Replace BASEB.<\/a><\/li>\n<\/ol>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/7398570507.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C6753: ASIC clock input error (back side) Rank C Trouble detection condition When starting the machine, verification on reading and writing the predetermined value for CPU (image processing section) on CPU board (CPUB) was conducted, and verification failure was detected. Trouble isolation Scanner Relevant electrical parts DF CIS module (DF CIS)CPU board &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6753-c4751i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C6753 (C4751i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":227,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1397],"epkb_post_type_1_tag":[],"class_list":["post-26341","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c6-4750i-4050i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26341","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/227"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=26341"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26341\/revisions"}],"predecessor-version":[{"id":26342,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26341\/revisions\/26342"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=26341"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=26341"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=26341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}