{"id":26438,"date":"2025-06-11T15:25:48","date_gmt":"2025-06-11T15:25:48","guid":{"rendered":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=26438"},"modified":"2025-06-11T15:25:53","modified_gmt":"2025-06-11T15:25:53","slug":"b17-c4751i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=b17-c4751i","title":{"rendered":"B17# (C4751i)"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Error code<\/th><th>Category<\/th><th>Contents of error<\/th><th>Solution<\/th><\/tr><\/thead><tbody><tr><td>B170<\/td><td rowspan=\"6\">MFP soft error<\/td><td>Program control error (table control error)<\/td><td rowspan=\"10\">Turn OFF and ON the main power switch.Acquire the data saved in the storage from [Service Mode] -&gt; [Debug Settings] -&gt; [Debug Log Output].Use the latest FW.Disconnect and then connect the connector of the base board.Execute self-diagnosis for all items.Try replacing parts. Memory, storage and base board<\/td><\/tr><tr><td>B171<\/td><td>Program control error (instance acquisition error)<\/td><\/tr><tr><td>B172<\/td><td>Timeout error<\/td><\/tr><tr><td>B173<\/td><td>Program control error (interface error)<\/td><\/tr><tr><td>B174<\/td><td>Semaphore acquisition\/release error<\/td><\/tr><tr><td>B175<\/td><td>Observer registration error<\/td><\/tr><tr><td>B176<\/td><td>Memory allocation error<\/td><td>Unable to secure domain for header (TTI) image generation<\/td><\/tr><tr><td>B177<\/td><td rowspan=\"3\">Image processing error<\/td><td>Header (TTI) image generation error<\/td><\/tr><tr><td>B178<\/td><td>Receiving job generation error<\/td><\/tr><tr><td>B179<\/td><td>Sequence control error (line command error\/mismatched status, mismatched event)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4751iService\/en-US\/7372352523.html\">(Link to the Field Service Manual)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Error code Category Contents of error Solution B170 MFP soft error Program control error (table control error) Turn OFF and ON the main power switch.Acquire the data saved in the storage from [Service Mode] -&gt; [Debug Settings] -&gt; [Debug Log Output].Use the latest FW.Disconnect and then connect the connector of the base board.Execute self-diagnosis for &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=b17-c4751i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;B17# (C4751i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":227,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1445],"epkb_post_type_1_tag":[],"class_list":["post-26438","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-cb-4751i-4750i-4051i-4050i-trouble"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26438","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/227"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=26438"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26438\/revisions"}],"predecessor-version":[{"id":26439,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/26438\/revisions\/26439"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=26438"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=26438"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=26438"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}