{"id":2817,"date":"2019-05-22T17:58:28","date_gmt":"2019-05-22T17:58:28","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=2817"},"modified":"2023-12-27T16:50:38","modified_gmt":"2023-12-27T16:50:38","slug":"cd012-bizhub-c554e-c454e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd012-bizhub-c554e-c454e","title":{"rendered":"CD012 (bizhub C554e\/C454e)"},"content":{"rendered":"\n<p>CD012 Contents <\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\nTrouble type<\/td><td>\nMount error due to hard disk being \nunformatted<\/td><\/tr><tr><td>\nTrouble code<\/td><td>\nCD012<\/td><\/tr><tr><td>\nRank<\/td><td>\nC<\/td><\/tr><tr><td>\nDetection timing<\/td><td> The hard disk is not logically formatted  after the whole <a href=\"..\/D0001049105\/D0001049105.html\"><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0001049105\/D0001049105.html\">data in  the hard disk has been deleted by overwriting<\/a><\/a>. The hard disk that has replaced an old one  is not logically formatted. <\/td><\/tr><tr><td>\nTrouble isolation<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\nRelevant electrical parts<\/td><td>\nHard \ndisk<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n&nbsp;\n(2)Procedure\n\n\n\n\n<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>\nStep<\/td><td>\nAction<\/td><td>\nControl signal<\/td><td>\nLocation of electrical \ncomponents<\/td><\/tr><\/thead><tbody><tr><td>\n1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0001049296\/D0001049296.html\"> <\/a><a href=\"..\/D0001049296\/D0001049296.html\"><\/a><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0001049296\/D0001049296.html\">Logically format<\/a> the hard disk and then<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000998587\/D0000998587.html\"> <\/a><a href=\"..\/D0000998587\/D0000998587.html\"><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000998587\/D0000998587.html\">upgrade the  firmwar<\/a>e<\/a>.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n2<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997480\/D0000997480.html\"> <\/a><a href=\"..\/D0000997480\/D0000997480.html\"><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997480\/D0000997480.html\">Replace the hard disk<\/a>.<\/a> (Part# A2X0M72C00)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>\n\nLink to the layout drawings for related parts by \neach trouble code (<a href=\"..\/D0001089956\/D0001089956.html\">S.130. \nCD011, CD012, CD041, CD042, CD043, CD044, CD045, CD046, CD047, CD048, CD049, \nCD04A, CD04B<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual) <a rel=\"noreferrer noopener\" href=\"http:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0001298423\/D0001298423.html\" target=\"_blank\">K.3.16.5 CD012<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>CD012 Contents Trouble type Mount error due to hard disk being unformatted Trouble code CD012 Rank C Detection timing The hard disk is not logically formatted after the whole data in the hard disk has been deleted by overwriting. The hard disk that has replaced an old one is not logically formatted. Trouble isolation &#8211; &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd012-bizhub-c554e-c454e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;CD012 (bizhub C554e\/C454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[1006],"epkb_post_type_1_tag":[],"class_list":["post-2817","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-cd-c554e-c454e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/2817","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2817"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/2817\/revisions"}],"predecessor-version":[{"id":11138,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/2817\/revisions\/11138"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2817"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=2817"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=2817"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}