{"id":2958,"date":"2019-05-23T14:41:39","date_gmt":"2019-05-23T14:41:39","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=2958"},"modified":"2023-12-27T16:48:20","modified_gmt":"2023-12-27T16:48:20","slug":"c1156-bizhub-c554e-c454e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1156-bizhub-c554e-c454e","title":{"rendered":"C1156 (bizhub C554e\/C454e)"},"content":{"rendered":"\n<p>\n\n(1)Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>SD paddle motors malfunction (trailing edge)<\/td><\/tr><tr><td>Trouble code<\/td><td>C1156<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When FS-534+SD-511 is installed&gt; <br>The paddle home sensor (PS5) is not blocked or unblocked even after the set period of time has elapsed while the SD paddle motor (M7) is energized. <br><br>&lt;When FS-535+SD-512 is installed&gt; <br>The paddle home sensor (PS5) is not blocked or unblocked even after the set period of time has elapsed while the SD paddle motor (M7) is energized. <\/td><td><\/td><\/tr><tr><td>Trouble isolation<\/td><td>Half-Fold\/Tri-Fold Center Stapling<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-534+SD-511 is installed&gt; <br>\u2022 SD paddle motor (M7) <br>\u2022 Paddle home sensor (PS5) <br>\u2022 SD drive board (SDDB) <br>\u2022 FS control board (FSCB) <br><br>&lt;When FS-535+SD-512 is installed&gt; <br>\u2022 SD paddle motor (M7) <br>\u2022 Paddle home sensor (PS5) <br>\u2022 SD drive board (SDDB) <br>\u2022 FS control board (FSCB) <\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)ProcedureWhen FS-534+SD-511 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M7-SDDB J8 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M7 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS5-SDDB J8 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td>PS5 I\/O check, sensor check<\/td><td>SDDB J8-3 (ON)<\/td><td>SD-511 3 to 4-G<\/td><\/tr><tr><td>7<\/td><td>M7 operation check<\/td><td>SDDB J8-4 to 7<\/td><td>SD-511 3-F to G<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997748\/D0000997748.html\">Replace M7<\/a> (Part# A3ERPP3M00)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>9<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997741\/D0000997741.html\">Replace SDDB<\/a> (Part# A3ERPP6J03)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>10<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997722\/D0000997722.html\">Replace FSCB<\/a> (Part# A3EPPPBE01)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000999095\/D0000999095.html\">N.3.9 SD-511<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0001089874\/D0001089874.html#sct_3\">S.46.1 SD-511<\/a>)<\/li><\/ul>\n\n\n\n<p>When FS-535+SD-512 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between M7-SDDB J8 for proper connection, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of M7 for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS5-SDDB J8 for proper connection, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS5 I\/O check, sensor check<\/td><td>SDDB J8-3 (ON)<\/td><td>SD-512 3-G<\/td><\/tr><tr><td>5<\/td><td>M7 operation check<\/td><td>SDDB J8-4 to 7<\/td><td>SD-512 3-F to G<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997686\/D0000997686.html\">Replace M7<\/a> (Part# A3EPPP5500)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997679\/D0000997679.html\">Replace SDDB<\/a> (Part# A3ERPP6J03)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997649\/D0000997649.html\">Replace FSCB<\/a> (Part# A2Y1H10002)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000999098\/D0000999098.html\">N.3.12 SD-512<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0001089874\/D0001089874.html#sct_4\">S.46.2 SD-512<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000998737\/D0000998737.html\" target=\"_blank\">K.3.6.33<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>(1)Contents Trouble type SD paddle motors malfunction (trailing edge) Trouble code C1156 Rank B Detection timing &lt;When FS-534+SD-511 is installed&gt; The paddle home sensor (PS5) is not blocked or unblocked even after the set period of time has elapsed while the SD paddle motor (M7) is energized. &lt;When FS-535+SD-512 is installed&gt; The paddle home sensor &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1156-bizhub-c554e-c454e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1156 (bizhub C554e\/C454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[952],"epkb_post_type_1_tag":[],"class_list":["post-2958","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-c554e-c454e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/2958","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2958"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/2958\/revisions"}],"predecessor-version":[{"id":15905,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/2958\/revisions\/15905"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2958"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=2958"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=2958"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}