{"id":3291,"date":"2019-05-23T19:58:21","date_gmt":"2019-05-23T19:58:21","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=3291"},"modified":"2023-12-27T15:52:05","modified_gmt":"2023-12-27T15:52:05","slug":"c2563-bizhub-c554e-c454e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2563-bizhub-c554e-c454e","title":{"rendered":"C2563 (bizhub C554e\/C454e)"},"content":{"rendered":"\n<p>(1)Contents<\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>Trouble type<\/td><td>Yellow TCR sensor failure<\/td><\/tr><tr><td>Trouble code<\/td><td>C2563: Yellow TCR sensor failure<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>\u2013<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Developing unit\/Y,M,C,K&nbsp;<br>\u2022 Front side board (FRB)&nbsp;<br>\u2022 Printer control board (PRCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)Procedure<\/p>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Reinstall developing unit<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>2<\/td><td>Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>3<\/td><td>Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary.<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997367\/D0000997367.html\">Replace the developing unit<\/a>&nbsp;(Part# A2XN08D)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997494\/D0000997494.html\">Replace FRB<\/a>&nbsp;(Parts# A7PUH00500)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997497\/D0000997497.html\">Replace PRCB<\/a>\u00a0(C554e Part# A5AYH00101 \/ C454e Part# A5C0H00101)<\/td><td>\u2013<\/td><td>\u2013<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li> Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0001089891\/D0001089891.html\">S.64. C2413, C2556, C2563<\/a><strong>)<\/strong> <\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"http:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000998756\/D0000998756.html\" target=\"_blank\">K.3.7.10<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>(1)Contents Trouble type Yellow TCR sensor failure Trouble code C2563: Yellow TCR sensor failure Rank B Detection timing TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value. Trouble isolation \u2013 Relevant electrical parts \u2022 Developing unit\/Y,M,C,K&nbsp;\u2022 Front side board (FRB)&nbsp;\u2022 Printer control board (PRCB) &nbsp;(2)Procedure Step Action Control signal &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2563-bizhub-c554e-c454e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2563 (bizhub C554e\/C454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[953],"epkb_post_type_1_tag":[],"class_list":["post-3291","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c554e-c454e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3291"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3291\/revisions"}],"predecessor-version":[{"id":12390,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3291\/revisions\/12390"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3291"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=3291"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=3291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}