{"id":3547,"date":"2019-05-24T16:41:48","date_gmt":"2019-05-24T16:41:48","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=3547"},"modified":"2023-12-27T14:24:25","modified_gmt":"2023-12-27T14:24:25","slug":"75-42-bizhub-c554e-c454e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=75-42-bizhub-c554e-c454e","title":{"rendered":"75-42 (bizhub C554e\/C454e)"},"content":{"rendered":"\n<p>\n\n(1)Contents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>RU section<\/td><\/tr><tr><td>JAM code<\/td><td>75-42<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When FS-534 is installed> <br>The RU entrance sensor (PS2) is not locked even after the set period of time has elapsed after the copier&#8217;s paper exit sensor (PS3) is unlocked by the paper.<br><br>&lt;When FS-535 is installed> <br>The RU transport sensor (PS60) is not locked even after the set period of time has elapsed after the copier&#8217;s paper exit sensor (PS3) is unlocked by the paper. <\/td><td><\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Horizontal transport cover<\/td><\/tr><tr><td>Relevant parts<\/td><td>&lt;When FS-534 is installed> <br>\u2022 Paper exit sensor (PS3) <br>\u2022 RU entrance sensor (PS2) <br>\u2022 FS control board (FSCB)  <br><br>&lt;When FS-535 is installed> <br>\u2022 Paper exit sensor (PS3) <br>\u2022 RU transport sensor (PS60) <br>\u2022 RU control board (RUCB) <br>\u2022 FS control board (FSCB) <\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)ProcedureWhen FS-534 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000998609\/D0000998609.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS3 I\/O check, sensor check<\/td><td>PRCB CN21-7 (ON)<\/td><td>bizhub C554e\/C454e 16-C<\/td><\/tr><tr><td>3<\/td><td>PS2 I\/O check, sensor check<\/td><td>FSCB J6-7 (ON)<\/td><td>FS-534 6-K<\/td><\/tr><tr><td>4<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997722\/D0000997722.html\">Replace FSCB<\/a> (Part # A3EPPPBE01)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000999085\/D0000999085.html\">N.1. bizhub C554e\/C454e<\/a>)<\/li><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000999094\/D0000999094.html\">N.3.8 FS-534<\/a>)<\/li><\/ul>\n\n\n\n<p>When FS-535 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical component<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000998609\/D0000998609.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS3 I\/O check, sensor check<\/td><td>PRCB CN21-7 (ON)<\/td><td>bizhub C554e\/C454e 16-C<\/td><\/tr><tr><td>3<\/td><td>PS60 I\/O check, sensor check<\/td><td>RUCB CN206-3 (ON)<\/td><td>FS-535 3-P to Q<\/td><\/tr><tr><td>4<\/td><td>RUCB ICP1 conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997650\/D0000997650.html\">Replace RUCB<\/a> (Part#  A2Y1H10101)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000997649\/D0000997649.html\">Replace FSCB<\/a> (Part# A2Y1H10002)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000999085\/D0000999085.html\">N.1. bizhub C554e\/C454e<\/a>)<\/li><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000999096\/D0000999096.html\">N.3.10 FS-535<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC454eC554eService\/D0000998667\/D0000998667.html\" target=\"_blank\">K.1.10.41<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>(1)Contents JAM type RU section JAM code 75-42 Detection timing &lt;When FS-534 is installed> The RU entrance sensor (PS2) is not locked even after the set period of time has elapsed after the copier&#8217;s paper exit sensor (PS3) is unlocked by the paper. &lt;When FS-535 is installed> The RU transport sensor (PS60) is not locked &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=75-42-bizhub-c554e-c454e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;75-42 (bizhub C554e\/C454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[523],"epkb_post_type_1_tag":[],"class_list":["post-3547","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-72-c554e-c454e-jam-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3547"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3547\/revisions"}],"predecessor-version":[{"id":3557,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3547\/revisions\/3557"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3547"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=3547"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=3547"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}