{"id":3619,"date":"2019-05-28T16:57:35","date_gmt":"2019-05-28T16:57:35","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=3619"},"modified":"2023-12-27T14:10:57","modified_gmt":"2023-12-27T14:10:57","slug":"c0211-bizhub-368e-308e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0211-bizhub-368e-308e","title":{"rendered":"C0211 (bizhub 368e\/308e)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C0211: Manual feed up\/down abnormality<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>\u2022 The bypass lift-up position sensor (PS26) is not turned OFF (unblock) even after the paper feed motor (M22) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. <br>\u2022 The bypass lift-up position sensor (PS26) is not turned ON (blocked) even after the paper feed motor (M22) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Manual<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Paper feed motor (M22) <br>\u2022 Bypass pick-up solenoid (SD1) <br>\u2022 Bypass lift-up position sensor (PS26) <br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M22-MFPB CN16E for proper connection and correct as necessary.<\/li><li>Check the connector of M22 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS26-relay CN19-MFPB CN18E for proper connection and correct as necessary.<\/li><li>Check the connector between SD1-relay CN21-relay CN19-MFPB CN18E for proper connection and correct as necessary.<\/li><li>PS26 I\/O check, sensor check<ul><li>Control signal: MFPB CN18E-13 (ON)<\/li><li>Location of electrical component: 22-J<\/li><\/ul><\/li><li>SD1 load check<ul><li>Check code: 23<\/li><li>Multi code: 3<\/li><li>Control signal: MFPB CN18E-10 (ON)<\/li><li>Location of electrical component: 22-J<\/li><\/ul><\/li><li>M22 load check<ul><li>Check code: 28<\/li><li>Multi code: 25, 26, 27, 28<\/li><li>Control signal: MFPB CN16E-1 to 4<\/li><li>Location of electrical component: 13-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4739113739.html\">Replace M22.<\/a> (Part# A61DM10000)<\/li><li>MFPB ICP3E conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4738908683.html\">Replace MFPB.<\/a> (Part# AA6VH02101)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4778224267.html\">L.3.7.13<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C0211: Manual feed up\/down abnormality Rank B Trouble detection condition \u2022 The bypass lift-up position sensor (PS26) is not turned OFF (unblock) even after the paper feed motor (M22) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position. &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0211-bizhub-368e-308e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C0211 (bizhub 368e\/308e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[563],"epkb_post_type_1_tag":[],"class_list":["post-3619","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c0-368e-308e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3619","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3619"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3619\/revisions"}],"predecessor-version":[{"id":3620,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3619\/revisions\/3620"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3619"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=3619"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=3619"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}