{"id":3703,"date":"2019-05-28T19:21:14","date_gmt":"2019-05-28T19:21:14","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=3703"},"modified":"2023-12-27T14:06:03","modified_gmt":"2023-12-27T14:06:03","slug":"c6754-bizhub-368e-308e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6754-bizhub-368e-308e","title":{"rendered":"C6754 (bizhub 368e\/308e)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C6754: CIS clamp adjustment failure (When DF-704 is installed)<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 CIS module (CIS) <br>\u2022 Dual scan image processing board (DSIPB) <br>\u2022 CIS power supply (CISPU) <br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Correct the harness connection between CIS and DSIPB if faulty.<\/li><li>Correct the harness connection between CIS J222-CISPU J2 if faulty.<\/li><li>Check for possible extraneous light and correct as necessary.<\/li><li>Clean the back side reading glass and the shading sheet if dirty.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/44726528114741538315.html\">Replace CIS.<\/a> (Part# A85GM70001)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/44726809714741541387.html\">Replace DSIPB.<\/a> (Part# A7PUH02A01)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/44726739314741540619.html\">Replace CISPU.<\/a> (Part#  A3CEPP4Y00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4738908683.html\">Replace MFPB.<\/a> (Part# AA6VH02101)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4837048075.html\">L.3.17.9<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C6754: CIS clamp adjustment failure (When DF-704 is installed) Rank B Trouble detection condition After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low. Trouble isolation Scanner Relevant electrical parts \u2022 CIS module (CIS) \u2022 Dual scan image processing board (DSIPB) \u2022 &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6754-bizhub-368e-308e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C6754 (bizhub 368e\/308e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[569],"epkb_post_type_1_tag":[],"class_list":["post-3703","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c6-368e-308e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3703","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3703"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3703\/revisions"}],"predecessor-version":[{"id":3707,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3703\/revisions\/3707"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3703"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=3703"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=3703"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}