{"id":373,"date":"2019-04-23T14:42:28","date_gmt":"2019-04-23T14:42:28","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=373"},"modified":"2023-12-27T18:17:46","modified_gmt":"2023-12-27T18:17:46","slug":"c1184-bizhub-c360i-c300i-c250i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1184-bizhub-c360i-c300i-c250i","title":{"rendered":"C1184 (bizhub C360i\/C300i\/C250i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1184: Paper receiving control motor drive malfunction<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>&lt;When\u00a0FS-536\u00a0or\u00a0FS-536SD\u00a0is installed> <br>The paper delivery control sensor (PS28) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the paper receiving control motor (M12) is energized. <\/td><td><\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When\u00a0FS-536\u00a0or\u00a0FS-536SD\u00a0is installed> <br>\u2022 Paper receiving control motor (M12) <br>\u2022 Paper delivery control sensor (PS28) <br>\u2022 FS control board (FSCB) <\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M12-relay CN1-FSCB J14 for proper connection and correct as necessary.<\/li><li>Check the connector of M12 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS28-relay CN1-FSCB J14 for proper connection and correct as necessary.<\/li><li>PS28 I\/O check, sensor check<ul><li>Control signal: FSCB J14&lt;B>-3 (ON)<\/li><li>Location of electrical component:\u00a0FS-536\/FS-536SD\u00a02 to 3-C<\/li><\/ul><\/li><li>M12 operation check<ul><li>Control signal: FSCB J14&lt;A>-9 to 12<\/li><li>Location of electrical component:\u00a0FS-536\/FS-536SD\u00a02-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6222536075.html\">Replace M12<\/a>. (Part#  A3EPPPAA00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6222420619.html\">Replace FSCB<\/a>. (Part# A87GPP0V00)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6374253579.html\">L.3.7.19<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C1184: Paper receiving control motor drive malfunction Rank B Trouble detection condition &lt;When\u00a0FS-536\u00a0or\u00a0FS-536SD\u00a0is installed> The paper delivery control sensor (PS28) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the paper receiving control motor (M12) is energized. Trouble isolation &#8211; Relevant electrical parts &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1184-bizhub-c360i-c300i-c250i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1184 (bizhub C360i\/C300i\/C250i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[936],"epkb_post_type_1_tag":[],"class_list":["post-373","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-c360i-c300i-c250i-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=373"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/373\/revisions"}],"predecessor-version":[{"id":8359,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/373\/revisions\/8359"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=373"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=373"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}