{"id":3850,"date":"2019-05-29T14:30:24","date_gmt":"2019-05-29T14:30:24","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=3850"},"modified":"2023-12-27T14:01:18","modified_gmt":"2023-12-27T14:01:18","slug":"c9401-bizhub-658e-558e-458e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c9401-bizhub-658e-558e-458e","title":{"rendered":"C9401 (bizhub 658e\/558e\/458e)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C9401: Exposure LED lighting failure<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>C9401: The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022LED exposure unit <br>\u2022 Flat cable (LED exposure unit) <br>\u2022 CCD board (CCDB) <br>\u2022 Scanner drive board (SCDB) <br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Correct the harness connection between SCDB CN3-LU201 if faulty.<\/li><li>Check the connector between SCDB CN2-MFPB CN6E for proper connection and correct as necessary.<\/li><li>Check the connector between CCDB PJ3-MFPB CN1 for proper connection and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4739858699.html\">Replace the LED exposure unit.<\/a> (Part# A7PUR71000)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740216075.html\">Replace CCDB.<\/a> (Part#  A795R71000 )<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740238859.html\">Replace SCDB.<\/a> (Part#  A796H01A00 )<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740318603.html\">Replace MFPB.<\/a>   (658e\/558e)(Part# AA6RH02103 ) ( <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740318603.html\">458e<\/a> )(Part #  AA6UH02101 )  <\/li><\/ol>\n\n\n\n<p> <strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual) <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4784937867.html\">L.3.22.1.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C9401: Exposure LED lighting failure Rank B Trouble detection condition C9401: The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment. Trouble isolation Scanner Relevant electrical parts \u2022LED exposure unit \u2022 Flat cable (LED exposure unit) \u2022 CCD board (CCDB) \u2022 Scanner drive board (SCDB) &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c9401-bizhub-658e-558e-458e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C9401 (bizhub 658e\/558e\/458e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[539],"epkb_post_type_1_tag":[],"class_list":["post-3850","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c9"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3850","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3850"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3850\/revisions"}],"predecessor-version":[{"id":4019,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3850\/revisions\/4019"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3850"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=3850"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=3850"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}