{"id":390,"date":"2019-04-23T16:34:56","date_gmt":"2019-04-23T16:34:56","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=390"},"modified":"2023-12-27T18:17:46","modified_gmt":"2023-12-27T18:17:46","slug":"c1402-bizhub-c360i-c300i-c250i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1402-bizhub-c360i-c300i-c250i","title":{"rendered":"C1402 (bizhub C360i\/C300i\/C250i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1402: FS nonvolatile memory error<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>&lt;When\u00a0FS-533\u00a0is installed> <br>When the main power switch is turned ON, malfunctioning of the nonvolatile memory on the FS control board (FSCB) is detected. <\/td><td><\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When\u00a0FS-533\u00a0is installed> <br>FS control board (FSCB) <\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.<\/li><li>Rewrite the firmware.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6222025227.html\">Replace FSCB<\/a>. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6374470795.html\">L.3.7.26<\/a> (Link to the Field Service Manual)<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C1402: FS nonvolatile memory error Rank C Trouble detection condition &lt;When\u00a0FS-533\u00a0is installed> When the main power switch is turned ON, malfunctioning of the nonvolatile memory on the FS control board (FSCB) is detected. Trouble isolation &#8211; Relevant electrical parts &lt;When\u00a0FS-533\u00a0is installed> FS control board (FSCB) Procedure Turn OFF the main power switch &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1402-bizhub-c360i-c300i-c250i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1402 (bizhub C360i\/C300i\/C250i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[936],"epkb_post_type_1_tag":[],"class_list":["post-390","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-c360i-c300i-c250i-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/390","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=390"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/390\/revisions"}],"predecessor-version":[{"id":8374,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/390\/revisions\/8374"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=390"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=390"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=390"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}