{"id":3968,"date":"2019-05-29T16:50:46","date_gmt":"2019-05-29T16:50:46","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=3968"},"modified":"2023-12-27T13:59:27","modified_gmt":"2023-12-27T13:59:27","slug":"32-01-bizhub-658e-558e-458e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=32-01-bizhub-658e-558e-458e","title":{"rendered":"32-01 (bizhub 658e\/558e\/458e)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at fusing\/paper exit section<\/td><\/tr><tr><td>JAM code<\/td><td>32-01<\/td><\/tr><tr><td>JAM detection timing<\/td><td>The ADU paper passage sensor\/1 (PS40) is not turned ON (unblocked) even after the lapse of a given period of time after the reverse sequence is started.<\/td><td><\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the exit section results, if the paper exit sensor (PS3) is turned ON (unblocked) when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.<\/td><\/tr><tr><td>&#8211;<\/td><td>Paper jam of a sheet of paper left at the exit section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.<\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Right door<\/td><\/tr><tr><td>Relevant parts<\/td><td>\u2022 Fusing motor (M3) <br>\u2022 Reverse motor (M4) <br>\u2022 ADU transport motor\/1 (M5) <br>\u2022 Paper exit clutch (CL8) <br>\u2022 Fusing loop sensor (PS2) <br>\u2022 Paper exit sensor (PS3) <br>\u2022 ADU paper passage sensor\/1 (PS40) <br>\u2022 Gate switch solenoid (SD3) <br>\u2022 Expansion control board (EXCB) <br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/37463415154776904971.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS2 I\/O check, sensor check<\/td><td>MFPB CN17E-16 (ON)<\/td><td>7-C<\/td><\/tr><tr><td>3<\/td><td>PS3 I\/O check, sensor check<\/td><td>MFPB CN17E-7 (ON)<\/td><td>7-C<\/td><\/tr><tr><td>4<\/td><td>PS40 I\/O check, sensor check<\/td><td>MFPB CN17E-10 (ON)<\/td><td>7-C<\/td><\/tr><tr><td>5<\/td><td>CL8 load checkCheck code: 21Multi code: 3<\/td><td>EXCB CN8&lt;A&gt;-6 (CL8_REM)<\/td><td>24-T<\/td><\/tr><tr><td>6<\/td><td>SD3 load checkCheck code: 83Multi code: 0<\/td><td>MFPB CN15E&lt;B&gt;-3 (SD3_24V)<\/td><td>658e\/558e 17-C458e 20-C<\/td><\/tr><tr><td>7<\/td><td>M3 load checkCheck code: 45Multi code: 1, 2, 3, 4, 5<\/td><td>MFPB CN14E-9 (REM)MFPB CN14E-12 (LOCK)<\/td><td>2-C<\/td><\/tr><tr><td>8<\/td><td>M4 load checkCheck code: 84Multi code: 1, 2, 3, 4, 5, 6, 7, 8<\/td><td>MFPB CN15E&lt;A&gt;-3 to 6<\/td><td>658e\/558e 15-C458e 19-C<\/td><\/tr><tr><td>9<\/td><td>M5 load checkCheck code: 85Multi code: 1, 2, 3, 4<\/td><td>MFPB CN17E-1 to 4<\/td><td>6-C<\/td><\/tr><tr><td>10<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740413195.html\">Replace EXCB.<\/a> (Part# A9HGH00501)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>11<\/td><td>MFPB F6E conduction check<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>12<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740318603.html\">Replace MFPB.<\/a> (658e\/558e Part# AA6RH02103 \/ 458e Part# AA6UH02101)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>L.1.13.2. (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type Misfeed at fusing\/paper exit section JAM code 32-01 JAM detection timing The ADU paper passage sensor\/1 (PS40) is not turned ON (unblocked) even after the lapse of a given period of time after the reverse sequence is started. &#8211; Paper jam of a sheet of paper left at the exit section results, &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=32-01-bizhub-658e-558e-458e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;32-01 (bizhub 658e\/558e\/458e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[587],"epkb_post_type_1_tag":[],"class_list":["post-3968","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-32-658e-558e-458e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3968","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3968"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3968\/revisions"}],"predecessor-version":[{"id":3971,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/3968\/revisions\/3971"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3968"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=3968"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=3968"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}