{"id":452,"date":"2019-04-24T13:56:08","date_gmt":"2019-04-24T13:56:08","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=452"},"modified":"2023-12-27T18:17:27","modified_gmt":"2023-12-27T18:17:27","slug":"c2561-bizhub-c360i-c300i-c250i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2561-bizhub-c360i-c300i-c250i","title":{"rendered":"C2561 (bizhub C360i\/C300i\/C250i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C2561: Cyan TCR sensor failure<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>\u2022Alarm signals for each TCR sensor is detected more than the predetermined number of times. <br>\u2022 This detection is used for detecting disconnection of TCR sensor connector.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Developing unit\/C,M,Y,K <br>\u2022 Expansion control board (EXCB) <br>\u2022 CPU board (CPUB) <br>\u2022 Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Reinstall the developing unit.<\/li><li>Check the connector between the developing unit\/C-relay CN251-relay CN248-EXCB CN6EX for proper connection and correct as necessary. <\/li><li>Check the connector between EXCB CN1EX-BASEB CN11E for proper connection and correct as necessary.<\/li><li>Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6351174411.html\">Replace the corresponding developing unit<\/a>.<\/li><li> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6355340427.html\">Replace EXCB<\/a>. (Part# AA2JH00500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/7343756427.html\">Replace CPUB<\/a>. (Part# AA2JH02N06)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6355451147.html\">Replace BASEB<\/a>. (Part# AA2JH02005) <\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6374807819.html\">L.3.8.12<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C2561: Cyan TCR sensor failure Rank B Trouble detection condition \u2022Alarm signals for each TCR sensor is detected more than the predetermined number of times. \u2022 This detection is used for detecting disconnection of TCR sensor connector. Trouble isolation &#8211; Relevant electrical parts \u2022 Developing unit\/C,M,Y,K \u2022 Expansion control board (EXCB) \u2022 &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2561-bizhub-c360i-c300i-c250i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2561 (bizhub C360i\/C300i\/C250i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[937],"epkb_post_type_1_tag":[],"class_list":["post-452","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c360i-c300i-c250i-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/452","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=452"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/452\/revisions"}],"predecessor-version":[{"id":8716,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/452\/revisions\/8716"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=452"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=452"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=452"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}