{"id":4632,"date":"2019-06-03T16:52:42","date_gmt":"2019-06-03T16:52:42","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=4632"},"modified":"2023-12-21T19:39:00","modified_gmt":"2023-12-21T19:39:00","slug":"c3926-bizhub-368e-308e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3926-bizhub-368e-308e","title":{"rendered":"C3926 (bizhub 368e\/308e)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C3926: Fusing sensor wire breaks detection (Center of the heating roller)<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>After a predetermined period of time after the warm-up stage is started, the heating roller thermistor\/1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>\u2013<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Fusing unit\u00a0<br>\u2022 Heating roller thermistor\/2 (TH2)<br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the fusing unit for correct installation (whether it is secured in position).<\/li><li>Check the open\/close operation of the right door.<\/li><li>Check the fusing unit and MFPB for proper connection and correct or change as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4735680139.html\">Replace the fusing unit.<\/a>&nbsp;(Part# A79JR71033)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4738908683.html\">Replace MFPB.<\/a>&nbsp;(Part# AA6VH02101)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4780559243.html\">L.3.11.8&nbsp;<\/a>(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C3926: Fusing sensor wire breaks detection (Center of the heating roller) Rank A Trouble detection condition After a predetermined period of time after the warm-up stage is started, the heating roller thermistor\/1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time. Trouble isolation \u2013 Relevant &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3926-bizhub-368e-308e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3926 (bizhub 368e\/308e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[566],"epkb_post_type_1_tag":[],"class_list":["post-4632","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-368e-308e"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4632","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4632"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4632\/revisions"}],"predecessor-version":[{"id":4633,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4632\/revisions\/4633"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4632"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=4632"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=4632"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}