{"id":4648,"date":"2019-06-03T17:36:43","date_gmt":"2019-06-03T17:36:43","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=4648"},"modified":"2023-12-21T19:39:00","modified_gmt":"2023-12-21T19:39:00","slug":"c3425-bizhub-658e-558e-458e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3425-bizhub-658e-558e-458e","title":{"rendered":"C3425 (bizhub 658e\/558e\/458e)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C3425: Fusing warm-up trouble<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>\u2022 Detected temperature of the heating roller temperature sensor\/1 (TEMS\/1) or heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up. <br>\u2022 The temperature detected by the heating roller temperature sensor\/1 (TEMS\/1) or heating roller temperature sensor (TEMS) does not shift from the pre-standby state or the post-print printing-enable wait state even after the lapse of a predetermined period of time after the completion of warm-up.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Fusing unitHeating roller temperature sensor\/1 (TEMS\/1) (bizhub 658e\/558e) <br>\u2022 Heating roller temperature sensor (TEMS) (bizhub 458e) <br>\u2022 DC power supply (DCPU) <br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the fusing unit for correct installation (whether it is secured in position).<\/li><li>Check the open\/close operation of the right door.<\/li><li>Check the fusing unit, DCPU, and MFPB for proper connection and correct or change as necessary.<\/li><li>Replace the fusing unit. (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4735702155.html\">bizhub 658e\/558e<\/a>\u00a0Part# A79JR71077 \/\u00a0<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4735680139.html\">bizhub 458e<\/a> Part# AA6UR70400)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740283275.html\">Replace DCPU.<\/a> (Part# AA6RR70400)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740318603.html\">Replace MFPB.<\/a> (658e\/558e Part# AA6RH02103 \/ 458e Part# AA6UH02101)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4780702859.html\">L.3.12.5<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C3425: Fusing warm-up trouble Rank A Trouble detection condition \u2022 Detected temperature of the heating roller temperature sensor\/1 (TEMS\/1) or heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up. \u2022 The temperature detected by the &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3425-bizhub-658e-558e-458e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3425 (bizhub 658e\/558e\/458e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[534],"epkb_post_type_1_tag":[],"class_list":["post-4648","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4648","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4648"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4648\/revisions"}],"predecessor-version":[{"id":4649,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4648\/revisions\/4649"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4648"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=4648"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=4648"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}