{"id":4689,"date":"2019-06-03T18:34:48","date_gmt":"2019-06-03T18:34:48","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=4689"},"modified":"2023-12-21T19:38:44","modified_gmt":"2023-12-21T19:38:44","slug":"c3b07-bizhub-658e-558e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3b07-bizhub-658e-558e","title":{"rendered":"C3B07 (bizhub 658e\/558e)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C3B07: IH input power error (bizhub 658e\/558e)<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>\u2022 While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time. <br>\u2022 While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time. <br>\u2022 While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. <br>\u2022 While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time. <br>\u2022 While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time. <br>\u2022 While the IH heater was ON, output voltage halt was detected.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Fusing unitIH coil (IHC) <br>\u2022 IH power supply (IHPU) <br>\u2022 NF board (NFB) <br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the fusing unit for correct installation (whether it is secured in position).<\/li><li>Check the fusing unit-MFPB CN22E for proper connection and correct or change as necessary.<\/li><li>Check the connector between NFB CN2-IHPU CN1 for proper connection and correct as necessary.<\/li><li>Check the connector between IHPU CN8-MFPB CN3E for proper connection and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740056715.html\">Replace IHC.<\/a> (Part# A79JM40C00) <\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740453899.html\">Replace IHPU.<\/a> (Part# A8KNM40A02)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740461963.html\">Replace NFB.<\/a> (Part# A795M40J00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4740318603.html\">Replace MFPB.<\/a> (Part# AA6RH02103)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub658eservice\/en-US\/4780885643.html\">L.3.12.13<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C3B07: IH input power error (bizhub 658e\/558e) Rank A Trouble detection condition \u2022 While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time. \u2022 While the IH heater was ON, input power was at the low &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3b07-bizhub-658e-558e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3B07 (bizhub 658e\/558e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[534],"epkb_post_type_1_tag":[],"class_list":["post-4689","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4689"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4689\/revisions"}],"predecessor-version":[{"id":4690,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/4689\/revisions\/4690"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4689"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=4689"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=4689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}