{"id":5418,"date":"2019-06-10T14:56:20","date_gmt":"2019-06-10T14:56:20","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=5418"},"modified":"2023-12-21T18:10:40","modified_gmt":"2023-12-21T18:10:40","slug":"c1140-bizhub-558-458-368-308","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1140-bizhub-558-458-368-308","title":{"rendered":"C1140 (bizhub 558\/458\/368\/308)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1140: Alignment motor\/rear drive malfunction<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>&lt;When FS-533 is installed> <br>\u2022 The alignment plate home sensor\/R (PS109) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. <br>\u2022 The alignment plate home sensor\/R (PS109) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor\/R (M106) is energized when the plate returns to the home position. <\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-536 or FS-536SD is installed><br>The alignment plate\/R home sensor (PS13) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the alignment motor\/rear (M8) is energized.<\/td><\/tr><tr><td><\/td><td>&lt;When FS-537 or FS-537SD is installed><br>The alignment plate\/R home sensor (PS6) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the alignment motor\/rear (M13) is energized.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-533 is installed> <br>\u2022 Alignment motor\/R (M106) <br>\u2022 Alignment plate home sensor\/R (PS109) <br>\u2022 FS control board (FSCB) <\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When FS-536 or FS-536SD is installed><br>\u2022 Alignment motor\/rear (M8) <br>\u2022 Alignment plate\/R home sensor (PS13) <br>\u2022 FS control board (FSCB)<\/td><\/tr><tr><td><\/td><td>&lt;When FS-537 or FS-537SD is installed><br>\u2022 Alignment motor\/rear (M13) <br>\u2022 Alignment plate\/R home sensor (PS6) <br>\u2022 FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E20465335333320697320696E7374616C6C6564\">&nbsp;When FS-533 is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M106-FSCB CN102 for proper connection and correct as necessary.<\/li><li>Check the connector of M106 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS109-FSCB CN102 for proper connection and correct as necessary.<\/li><li>PS109 I\/O check, sensor check<ul><li>Control signal: FSCB CN102<\/li><li>Location of electrical component: FS-533 7-J<\/li><\/ul><\/li><li>M106 operation check<ul><li>Control signal: FSCB CN102<\/li><li>Location of electrical component: FS-533 8-J<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/19211402354580904971.html\">Replace M106<\/a> (Part#  A2YUPPW600)<\/li><li>FSCB CP105 conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/19210910834580893451.html\">Replace FSCB<\/a> (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/19447901554585728011.html\">FS-533<\/a>)<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353336206F72204653353336534420697320696E7374616C6C6564\">&nbsp;When FS-536 or FS-536SD is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M8-FSCB J12 for proper connection and correct as necessary.<\/li><li>Check the connector of M8 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS13-FSCB J9 for proper connection and correct as necessary.<\/li><li>PS13 I\/O check, sensor check<ul><li>Control signal: FSCB J9&lt;B>-11 (ON)<\/li><li>Location of electrical component: FS-536\/FS-536SD 10-C<\/li><\/ul><\/li><li>M8 operation check<ul><li>Control signal: FSCB J12-13 to 16 (ON)<\/li><li>Location of electrical component: FS-536\/FS-536SD 6-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/37384678514580953611.html\">Replace M8.<\/a> (Part#  A3EPPP5500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/37384185714580940171.html\">Replace FSCB.<\/a> (Part# A87GPP0V00)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/37547087474585733003.html\">FS-536\/FS-536SD<\/a>)<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353337206F72204653353337534420697320696E7374616C6C6564\">&nbsp;When FS-537 or FS-537SD is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M13-relay CN3-FSCB J21 for proper connection and correct as necessary.<\/li><li>Check the connector of M13 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS6-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary.<\/li><li>PS6 I\/O check, sensor check<ul><li>Control signal: FSCB J21-10 (ON)<\/li><li>Location of electrical component: FS-537\/FS-537SD 4-D<\/li><\/ul><\/li><li>M13 operation check<ul><li>Control signal: FSCB J21-1 to 4<\/li><li>Location of electrical component: FS-537\/FS-537SD 4-D<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/37379343474581041931.html\">Replace M13.<\/a> (Part# A87HPPAD00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/37378780274581026571.html\">Replace FSCB.<\/a> (Part# A87HPP9M01)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/37546805874585734667.html\">FS-537\/FS-537SD<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/4569207691.html\">K.3.9.22<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C1140: Alignment motor\/rear drive malfunction Rank B Trouble detection condition &lt;When FS-533 is installed> \u2022 The alignment plate home sensor\/R (PS109) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. \u2022 The alignment plate home sensor\/R (PS109) is not &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1140-bizhub-558-458-368-308\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1140 (bizhub 558\/458\/368\/308)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[602,603],"epkb_post_type_1_tag":[],"class_list":["post-5418","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-558-458-trouble-code","epkb_post_type_1_category-c1-368-308"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5418","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5418"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5418\/revisions"}],"predecessor-version":[{"id":5419,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5418\/revisions\/5419"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5418"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=5418"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=5418"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}