{"id":5512,"date":"2019-06-11T14:46:53","date_gmt":"2019-06-11T14:46:53","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=5512"},"modified":"2023-12-21T18:07:09","modified_gmt":"2023-12-21T18:07:09","slug":"c3101-bizhub-368-308","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3101-bizhub-368-308","title":{"rendered":"C3101 (bizhub 558\/458)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">&nbsp;Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C3101: Pressure roller pressure failure<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td> <br>C3101:<br>\u2022The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during pressure by the pressure roller.<br>\u2022The fusing pressure home sensor (PS38) is not blocked even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during pressure by the pressure roller. <\/td><\/tr><tr><td><\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022Fusing unit <br>\u2022 Fusing pressure motor (M11) <br>\u2022 Fusing pressure home sensor (PS38) <br>\u2022 MFP board (MFPB)(558)part# A9HGH02102 )(458)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M11-relay CN112-MFPB CN15E for proper connection and correct as necessary.<\/li><li>Check the connector between the fusing unit-relay CN96-MFPB CN22E for proper connection and correct as necessary. (bizhub 558)<\/li><li>Check the connector between the fusing unit-relay CN104-MFPB CN12E for proper connection and correct as necessary. (bizhub 458)<\/li><li>PS38 I\/O check, sensor check<ul><li>Control signal: 558 MFPB CN22E-9 (ON), 458 MFPB CN12E-12 (ON)<\/li><li>Location of electrical component: 558 22-C, 458 24-C<\/li><\/ul><\/li><li>M11 operation check<ul><li>Control signal: MFPB CN15E&lt;A&gt;-7 to 10<\/li><li>Location of electrical component: 558 16-C, 458 19-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/44718598514580755979.html\">Replace M11.&nbsp;<\/a>&nbsp;(558)(458) Part# A79K228101)<\/li><li>Replace the fusing unit. (558)Part# A79JR71044 )(458)Part# A79MR70222 )<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/4561640587.html\">Replace MFPB.<\/a>&nbsp;(558)Part# A9HGH02102 )(458)Part # A9HHH02102 )<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/4575989899.html\">bizhub 558\/458<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual) <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/4570399115.html\">K.3.12.1.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;Contents Trouble type C3101: Pressure roller pressure failure Rank B Trouble detection condition C3101:\u2022The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during pressure by the pressure roller.\u2022The fusing pressure home sensor (PS38) is not blocked even after the &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3101-bizhub-368-308\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3101 (bizhub 558\/458)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[606],"epkb_post_type_1_tag":[],"class_list":["post-5512","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-558-458-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5512","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5512"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5512\/revisions"}],"predecessor-version":[{"id":5575,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5512\/revisions\/5575"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5512"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=5512"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=5512"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}