{"id":5878,"date":"2019-06-14T16:40:17","date_gmt":"2019-06-14T16:40:17","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=5878"},"modified":"2023-12-21T17:53:01","modified_gmt":"2023-12-21T17:53:01","slug":"c6755-bizhub-558-458","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6755-bizhub-558-458","title":{"rendered":"C6755 (bizhub 558\/458)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C6754: CIS clamp adjustment failure<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Scanner<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 CIS module (CIS)&nbsp;<br>\u2022 Dual scan image processing board (DSIPB)&nbsp;<br>\u2022 CIS power supply (CISPU)&nbsp;<br>\u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Correct the harness connection between CIS and DSIPB if faulty.<\/li><li>Correct the harness connection between CIS J222-CISPU J2 if faulty.<\/li><li>Check for possible extraneous light and correct as necessary.<\/li><li>Clean the back side reading glass and the shading sheet if dirty.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/44726528114580804363.html\">Replace CIS.<\/a>&nbsp;(Part# A85GM70001)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/4561661707.html\">Replace DSIPB.<\/a>&nbsp;(Part# A7PUH02A01)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/44726739314580806667.html\">Replace CISPU.<\/a>&nbsp;(Part# A3CEPP4Y00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/4561640587.html\">Replace MFPB.<\/a>&nbsp;(558 Part# A9HGH02102 \/ 458 Part# A9HHH02102)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub368Service\/en-US\/4571785867.html\">K.3.19.9<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C6754: CIS clamp adjustment failure Rank B Trouble detection condition After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low. Trouble isolation Scanner Relevant electrical parts \u2022 CIS module (CIS)&nbsp;\u2022 Dual scan image processing board (DSIPB)&nbsp;\u2022 CIS power supply (CISPU)&nbsp;\u2022 MFP board &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c6755-bizhub-558-458\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C6755 (bizhub 558\/458)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[614],"epkb_post_type_1_tag":[],"class_list":["post-5878","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c6-558-458-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=5878"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5878\/revisions"}],"predecessor-version":[{"id":5880,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/5878\/revisions\/5880"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5878"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=5878"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=5878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}