{"id":6200,"date":"2019-06-17T17:08:42","date_gmt":"2019-06-17T17:08:42","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=6200"},"modified":"2023-12-21T17:49:47","modified_gmt":"2023-12-21T17:49:47","slug":"c1103-bizhub-958-808","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-958-808","title":{"rendered":"C1103 (bizhub 958\/808)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C1103: Alignment motor\/Fronts drive malfunction<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>&lt;When FS-536 or FS-536SD is installed> <br>\u2022 The alignment plate\/F home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. <br>\u2022 The alignment plate\/F home sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor\/Front (M7) is turned ON to return the plate to the home position. <br>\u2022 The alignment plate\/F does not reach the specified position within the set period of time.  <br><br>&lt;When FS-537 or FS-537SD is installed>  <br>\u2022 The alignment plate\/F home sensor (PS9) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. <br>\u2022 The alignment plate\/F home sensor (PS9) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor\/Front (M14) is turned ON to return the plate to the home position. <br>\u2022 The alignment plate\/F does not reach the specified position within the set period of time. <\/td><td><\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-536 or FS-536SD is installed> <br>\u2022 Alignment motor\/Front (M7) <br>\u2022 Alignment plate\/F home sensor (PS12) <br>\u2022 FS control board (FSCB)  <br><br>&lt;When FS-537 or FS-537SD is installed>  <br>\u2022 Alignment motor\/Front (M14) <br>\u2022 Alignment plate\/F home sensor (PS9) <br>\u2022 FS control board (FSCB) <\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353336206F72204653353336534420697320696E7374616C6C6564\">&nbsp;When FS-536 or FS-536SD is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M7-FSCB J4 for proper connection and correct as necessary.<\/li><li>Check the connector of M7 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.<\/li><li>PS12 I\/O check, sensor check<ul><li>Control signal: FSCB J4&lt;B>-4 (ON)<\/li><li>Location of electrical component: FS-536\/FS-536SD 15-C<\/li><\/ul><\/li><li>M7 operation check<ul><li>Control signal: FSCB J4&lt;A>-5 to 8<\/li><li>Location of electrical component: FS-536\/FS-536SD 14-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3738460811.html\">Replace M7.<\/a> (Part# A3EPPP5500)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3738418571.html\">Replace FSCB.<\/a> (Part# A87GPP0V00)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3754708747.html\">FS-536\/FS-536SD<\/a>)<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E204653353337206F72204653353337534420697320696E7374616C6C6564\">&nbsp;When FS-537 or FS-537SD is installed<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M14-relay CN5-FSCB J18 for proper connection and correct as necessary.<\/li><li>Check the connector of M14 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS9-relay CN5-FSCB J18 for proper connection and correct as necessary.<\/li><li>PS9 I\/O check, sensor check<ul><li>Control signal: FSCB J18-10 (ON)<\/li><li>Location of electrical component: FS-537\/FS-537SD 6-D<\/li><\/ul><\/li><li>M14 operation check<ul><li>Control signal: FSCB J18-1 to 4<\/li><li>Location of electrical component: FS-537\/FS-537SD 6-D<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3737941387.html\">Replace M14.<\/a> (Part# A87HPPAD00)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3737878027.html\">Replace FSCB.<\/a> (Part# A87HPP9M01)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3754680587.html\">FS-537\/FS-537SD<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3748441995.html\">K.3.7.6<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C1103: Alignment motor\/Fronts drive malfunction Rank B Trouble detection condition &lt;When FS-536 or FS-536SD is installed> \u2022 The alignment plate\/F home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. \u2022 The alignment plate\/F home sensor (PS12) &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1103-bizhub-958-808\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1103 (bizhub 958\/808)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[681],"epkb_post_type_1_tag":[],"class_list":["post-6200","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-958-808-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6200","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6200"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6200\/revisions"}],"predecessor-version":[{"id":6206,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6200\/revisions\/6206"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6200"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=6200"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=6200"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}