{"id":6269,"date":"2019-06-17T18:04:28","date_gmt":"2019-06-17T18:04:28","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=6269"},"modified":"2023-12-21T17:48:48","modified_gmt":"2023-12-21T17:48:48","slug":"72-31-bizhub-958-808","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-31-bizhub-958-808","title":{"rendered":"72-31 (bizhub 958\/808)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>JAM type<\/td><td>Misfeed at JS exit section<\/td><\/tr><tr><td>JAM code<\/td><td>72-31<\/td><\/tr><tr><td>JAM detection timing<\/td><td>&lt;When FS-537+JS-602 or FS-537SD+JS-602 is installed> <br>The job tray paper exit sensor (PS402) is not turned ON (unblocked) even after the set period of time has elapsed after the route change gate home sensor (PS21) turns OFF (unblock) by the paper.  <\/td><td><\/td><td><\/td><\/tr><tr><td>Misfeed processing location<\/td><td>Separator cover<\/td><\/tr><tr><td>Relevant parts<\/td><td>&lt;When FS-537+JS-602 or FS-537SD+JS-602 is installed> <br>\u2022 Job tray paper exit sensor (PS402) <br>\u2022 FS control board (FSCB) <\/td><td><\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5768656E2046533533374A53363032206F7220465335333753444A5336303220697320696E7374616C6C6564\">&nbsp;When FS-537+JS-602 or FS-537SD+JS-602 is installed<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><th>Step<\/th><th>Action<\/th><th>Control signal<\/th><th>Location of electrical component<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3746341515.html\">Initial check items<\/a><\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>PS402 I\/O check, sensor check<\/td><td>FSCB J10-6 (ON)<\/td><td>FS-537\/FS-537SD 9-M<\/td><\/tr><tr><td>3<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3737878027.html\">Replace FSCB.<\/a> (Part# A87HPP9M01)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3754680587.html\">FS-537\/FS-537SD<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3747165195.html\">K.1.10.12<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents JAM type Misfeed at JS exit section JAM code 72-31 JAM detection timing &lt;When FS-537+JS-602 or FS-537SD+JS-602 is installed> The job tray paper exit sensor (PS402) is not turned ON (unblocked) even after the set period of time has elapsed after the route change gate home sensor (PS21) turns OFF (unblock) by the paper. &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=72-31-bizhub-958-808\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;72-31 (bizhub 958\/808)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[668],"epkb_post_type_1_tag":[],"class_list":["post-6269","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-72-958-808"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6269","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6269"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6269\/revisions"}],"predecessor-version":[{"id":6270,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6269\/revisions\/6270"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6269"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=6269"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=6269"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}