{"id":6451,"date":"2019-06-18T02:53:29","date_gmt":"2019-06-18T02:53:29","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=6451"},"modified":"2023-12-21T16:59:51","modified_gmt":"2023-12-21T16:59:51","slug":"c3102-bizhub-958-808","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3102-bizhub-958-808","title":{"rendered":"C3102  (bizhub 958\/808)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C3102: Heating roller failure to turn<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>During any state other than printing operation, the hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022    Fusing unit<br> \u2022    Fusing belt rotation sensor (PS56) (bizhub 958)<br> \u2022    Heating roller rotation sensor (PS56) (bizhub 808)<br> \u2022    Fusing motor (M30)<br> \u2022    MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the fusing unit for proper connection and correct as necessary.<\/li><li>Check the connector between M30-MFPB CN16E for proper connection and correct as necessary.<\/li><li>Check the connector of M30 for proper drive coupling and correct as necessary.<\/li><li>Check the fusing unit-relay CN260-MFPB CN30E for proper connection and correct or change as necessary.<\/li><li>PS56 I\/O check, sensor check<ul><li>Control signal: MFPB CN30E-14 (ON)<\/li><li>Location of electrical component: 9-C, 12-C<\/li><\/ul><\/li><li>M30 operation check<ul><li>Control signal: MFPB CN16E-4 (REM), MFPB CN16E-7 (LOCK)<\/li><li>Location of electrical component: 10-K<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3736826123.html\">Replace M30.<\/a> ( A796M10200 )<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3734514699.html\">Replace the fusing unit.<\/a> ( A796R71422 )<\/li><li> MFPB F2E or F14E conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3736581259.html\">Replace MFPB.<\/a> ( A796H02003)<\/li><\/ol>\n\n\n\n<p>NOTICE<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3754645387.html\">bizhub 958\/808\/758, bizhub PRO 958<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual) <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3749807755.html\">K.3.9.2<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C3102: Heating roller failure to turn Rank A Trouble detection condition During any state other than printing operation, the hard latch signal from one or both of the heating roller rotation latch detection 1 and the heating roller rotation latch detection 2 is turned ON. Trouble isolation &#8211; Relevant electrical parts \u2022 &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3102-bizhub-958-808\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3102  (bizhub 958\/808)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[683],"epkb_post_type_1_tag":[],"class_list":["post-6451","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-958-808-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6451"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6451\/revisions"}],"predecessor-version":[{"id":6452,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6451\/revisions\/6452"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6451"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=6451"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=6451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}