{"id":6684,"date":"2019-06-19T03:08:31","date_gmt":"2019-06-19T03:08:31","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=6684"},"modified":"2023-12-21T16:34:13","modified_gmt":"2023-12-21T16:34:13","slug":"c3726-bizhub-958-808","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3726-bizhub-958-808","title":{"rendered":"C3726  (bizhub 958\/808)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C3726: Fusing abnormally high temperature detection (Center of the heating roller)<\/td><\/tr><tr><td>Rank<\/td><td>A<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>C3726: Detected temperature of the fusing belt temperature sensor\/2 (TEMS2) goes beyond a given temperature for a given period of time consecutively.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211; C3726: Detected temperature of the heating roller temperature sensor\/2 (TEMS2) goes beyond a given temperature for a given period of time consecutively. <\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Fusing Unit   <br>\u2022 C3726: Fusing belt temperature sensor\/2 (TEMS2) (bizhub 958, bizhub PRO 958)<br>\u2022    C3726: Heating roller temperature sensor\/2 (TEMS2) (bizhub 808\/758)<br>\u2022 IH power supply unit (IHPU)<br> \u2022 Noise filter (NF1)<br> \u2022 MFP board (MFPB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the fusing unit for correct installation (whether it is secured in position).<\/li><li>Check the open\/close operation of the upper right door.<\/li><li>Check the fusing unit-MFPB CN30E for proper connection and correct or change as necessary.<\/li><li>Check the connector between TEMS1, TEMS2, TEMS3-relay CN512-MFPB CN29E for proper connection and correct as necessary.<\/li><li>Check the connector between NF1 CN2-IHPU CN1 for proper connection and correct as necessary.<\/li><li>Check the connector between IHPU CN8-MFPB CN18E for proper connection and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3734514699.html\">Replace the fusing unit.<\/a>\u00a0( 958)A796R71422 )( 808)A795R72922 )<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3736643339.html\">Replace IHPU.<\/a>\u00a0(958)( A796M40B00 )(808)( A8KNM40A02 )<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3736581259.html\">Replace MFPB.<\/a>\u00a0( A796H02003)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3736553099.html\">Replace NF1.<\/a>\u00a0(958)( A796M40H00 )(808)( A795M40J00 )<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual)&nbsp;<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3749934475.html\">K.3.9.10.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C3726: Fusing abnormally high temperature detection (Center of the heating roller) Rank A Trouble detection condition C3726: Detected temperature of the fusing belt temperature sensor\/2 (TEMS2) goes beyond a given temperature for a given period of time consecutively. Trouble isolation &#8211; C3726: Detected temperature of the heating roller temperature sensor\/2 (TEMS2) goes &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c3726-bizhub-958-808\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C3726  (bizhub 958\/808)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[683],"epkb_post_type_1_tag":[],"class_list":["post-6684","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c3-958-808-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6684","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6684"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6684\/revisions"}],"predecessor-version":[{"id":7033,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6684\/revisions\/7033"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6684"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=6684"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=6684"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}