{"id":6700,"date":"2019-06-19T14:41:06","date_gmt":"2019-06-19T14:41:06","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=6700"},"modified":"2023-12-21T16:34:13","modified_gmt":"2023-12-21T16:34:13","slug":"c265b-bizhub-958-808","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c265b-bizhub-958-808","title":{"rendered":"C265B (bizhub 958\/808)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"436F6E74656E7473\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>Trouble type<\/td><td>C265B: Main backup media access 2 error<\/td><\/tr><tr><td>Rank<\/td><td>C<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>\u2022 The re-written data, which has been read out, checked and founded as error, is read out again and found as error.&nbsp;<br>\u2022 The error was found when reading out the counter value.&nbsp;<br>\u2022 The main body detects that the back up board is not mounted.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>\u2013<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>Back up board\/2 (ERB\/2)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"50726F636564757265\">&nbsp;Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between ERB-MFPB CN5E for proper connection and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3736581259.html\">Replace MFPB.<\/a>\u00a0(Part# A796H02003)<\/li><li>Replace ERB. (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3736595339.html\">ERB\/2<\/a>\u00a0Part# A7AHH00C00)<\/li><li>If the above actions do not solve the problem, contact KM.<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub958\/en-US\/3749695115.html\">K.3.8.17<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C265B: Main backup media access 2 error Rank C Trouble detection condition \u2022 The re-written data, which has been read out, checked and founded as error, is read out again and found as error.&nbsp;\u2022 The error was found when reading out the counter value.&nbsp;\u2022 The main body detects that the back up &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c265b-bizhub-958-808\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C265B (bizhub 958\/808)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[682],"epkb_post_type_1_tag":[],"class_list":["post-6700","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-958-808-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6700","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6700"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6700\/revisions"}],"predecessor-version":[{"id":6704,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6700\/revisions\/6704"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6700"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=6700"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=6700"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}