{"id":6874,"date":"2019-06-19T19:52:06","date_gmt":"2019-06-19T19:52:06","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=6874"},"modified":"2023-12-21T16:32:45","modified_gmt":"2023-12-21T16:32:45","slug":"c2153-bizhub-c4050i-c3350i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2153-bizhub-c4050i-c3350i","title":{"rendered":"C2153 (bizhub C4050i\/C3350i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C2153: Transfer belt spacing fault at K pressure switching<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>C2153: The 1st transfer pressure switch (SW4) is not turned ON even after the lapse of a given period of time after the retraction operation started.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Color motor (M2) <br>\u2022 1st transfer pressure clutch (CL1) <br>\u2022 1st transfer pressure switch (SW4) <br>\u2022 CPU board (CPUB) <br>\u2022 Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M2-BASEB CN17E for proper connection and correct as necessary.<\/li><li>Check the connector of M2 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between SW4-BASEB CN18E for proper connection and correct as necessary.<\/li><li>Check the connector between CL1-relay CN13-BASEB CN18E for proper connection and correct as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li>SW4 I\/O check, sensor check<ul><li>Control signal: BASEB CN18E-3 (ON)<\/li><li>Location of electrical component: 2-C<\/li><\/ul><\/li><li>CL1 load check<ul><li>Check code: 24<\/li><li>Multi code: 1<\/li><li>Control signal: BASEB CN18E-4 (ON)<\/li><li>Location of electrical component: 2-C<\/li><\/ul><\/li><li>M2 load check<ul><li>Check code: 41<\/li><li>Multi code: 1, 2<\/li><li>Control signal: BASEB CN17E-11 to 15<\/li><li>Location of electrical component: 1-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408819851.html\">Replace M2.<\/a> (Part# AA2JM11100)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408636555.html\">Replace CPUB.<\/a> (Part# A93EH01004)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408577675.html\">Replace BASEB.<\/a> (Part# A93EH02007)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7397994379.html\">L.3.7.1<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C2153: Transfer belt spacing fault at K pressure switching Rank B Trouble detection condition C2153: The 1st transfer pressure switch (SW4) is not turned ON even after the lapse of a given period of time after the retraction operation started. Trouble isolation &#8211; Relevant electrical parts \u2022 Color motor (M2) \u2022 1st &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2153-bizhub-c4050i-c3350i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2153 (bizhub C4050i\/C3350i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[990],"epkb_post_type_1_tag":[],"class_list":["post-6874","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c4050i-c3350i-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6874","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6874"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6874\/revisions"}],"predecessor-version":[{"id":6898,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6874\/revisions\/6898"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6874"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=6874"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=6874"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}