{"id":6916,"date":"2019-06-19T20:14:55","date_gmt":"2019-06-19T20:14:55","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=6916"},"modified":"2023-12-21T16:32:25","modified_gmt":"2023-12-21T16:32:25","slug":"c2412-bizhub-c4050i-c3350i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2412-bizhub-c4050i-c3350i","title":{"rendered":"C2412 (bizhub C4050i\/C3350i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>Trouble type<\/td><td>C2412: Imaging unit\/M new article release<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>The status with the new unit is not cleared after the new imaging unit is set.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>\u2013<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Imaging unit\/C,M,Y,K&nbsp;<br>\u2022 CPU board (CPUB)&nbsp;<br>\u2022 Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Reinstall the imaging unit.<\/li><li>Check the connector between the imaging unit\/M-relay CN8-BASEB CN14E for proper connection and correct as necessary. (C2412)<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7424116363.html\">Replace the corresponding imaging unit.<\/a><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408636555.html\">Replace CPUB.<\/a>\u00a0(Part# A93EH01004)<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408577675.html\">Replace BASEB.<\/a>\u00a0(Part# A93EH02007)<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7398027147.html\">L.3.7.4<\/a>&nbsp;(Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C2412: Imaging unit\/M new article release Rank B Trouble detection condition The status with the new unit is not cleared after the new imaging unit is set. Trouble isolation \u2013 Relevant electrical parts \u2022 Imaging unit\/C,M,Y,K&nbsp;\u2022 CPU board (CPUB)&nbsp;\u2022 Base board (BASEB) Procedure Reinstall the imaging unit. Check the connector between the &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c2412-bizhub-c4050i-c3350i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C2412 (bizhub C4050i\/C3350i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[990],"epkb_post_type_1_tag":[],"class_list":["post-6916","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c2-c4050i-c3350i-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6916","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=6916"}],"version-history":[{"count":2,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6916\/revisions"}],"predecessor-version":[{"id":7104,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/6916\/revisions\/7104"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=6916"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=6916"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=6916"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}