{"id":7130,"date":"2019-06-20T14:38:18","date_gmt":"2019-06-20T14:38:18","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=7130"},"modified":"2023-12-21T16:30:49","modified_gmt":"2023-12-21T16:30:49","slug":"c5102-bizhub-c4050i-c3350i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c5102-bizhub-c4050i-c3350i","title":{"rendered":"C5102  (bizhub C4050i\/C3350i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C5102: Main motor failure to turn<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Trouble detection condition<\/td><td>C5102: The control circuit detects motor failure to turn while the motor is turning.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>&#8211;<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>\u2022 Main motor (M1) <br>\u2022  CPU board (CPUB) <br>\u2022  Base board (BASEB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M1-BASEB CN17E for proper connection and correct as necessary.<\/li><li>Check the loading status of the main drive, and correct the error as necessary.<\/li><li>Check CPUB for proper installation and correct as necessary.<\/li><li>M1 load check<ul><li>Check code: 40<\/li><li>Multi code: 1, 2<\/li><li>Control signal: BASEB CN17E-1 to 5<\/li><li>Location of electrical component: 1-C<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408786827.html\">Replace M1.<\/a> ( AA2JM11000 )<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408636555.html\">Replace CPUB.<\/a>  ( A93EH01004 ) <\/li><li>BASEB F18E conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7408577675.html\">Replace BASEB.<\/a> ( A93EH02007 )<\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual)  <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC4050iService\/en-US\/7398302091.html\">L.3.10.1.<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C5102: Main motor failure to turn Rank B Trouble detection condition C5102: The control circuit detects motor failure to turn while the motor is turning. Trouble isolation &#8211; Relevant electrical parts \u2022 Main motor (M1) \u2022 CPU board (CPUB) \u2022 Base board (BASEB) Procedure Check the connector between M1-BASEB CN17E for proper &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c5102-bizhub-c4050i-c3350i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C5102  (bizhub C4050i\/C3350i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[988],"epkb_post_type_1_tag":[],"class_list":["post-7130","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c5-c4050i-c3350i-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/7130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7130"}],"version-history":[{"count":1,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/7130\/revisions"}],"predecessor-version":[{"id":7134,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/7130\/revisions\/7134"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7130"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=7130"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=7130"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}