{"id":764,"date":"2019-04-26T20:35:31","date_gmt":"2019-04-26T20:35:31","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=764"},"modified":"2023-12-27T18:08:08","modified_gmt":"2023-12-27T18:08:08","slug":"c8101-bizhub-c360i-c300i-c250i","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c8101-bizhub-c360i-c300i-c250i","title":{"rendered":"C8101 (bizhub C360i\/C300i\/C250i)"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Contents<\/h2>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>C8101: Before reading pressure welding alienation mechanism (When&nbsp;DF-632&nbsp;or&nbsp;DF-714&nbsp;is installed)<\/td><td><\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><td><\/td><\/tr><tr><td>Trouble detection condition<\/td><td>&lt;When&nbsp;DF-632&nbsp;is installed&gt;<br>\u2022 During a pressure motion being performed, the reading roll position sensor (PS11) output does not change from H to L. <br>\u2022 During a retraction motion being performed, the reading roll position sensor (PS11) output does not change from L to H.<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When&nbsp;DF-714&nbsp;is installed&gt;<br>\u2022 During a pressure motion being performed, the reading roll position sensor (PS4) output does not change from H to L. <br>\u2022 During a retraction motion being performed, the reading roll position sensor (PS4) output does not change from L to H. <\/td><\/tr><tr><td>Trouble isolation<\/td><td>DF<\/td><td><\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When&nbsp;DF-632&nbsp;is installed&gt;<br>\u2022 Reading roll release motor (M5) <br>\u2022 Reading roll position sensor (PS11) <br>\u2022 DF control board (DFCB)<\/td><td><\/td><\/tr><tr><td><\/td><td>&lt;When&nbsp;DF-714&nbsp;is installed&gt;<br>\u2022 Reading roll release motor (M4) <br>\u2022 Reading roll position sensor (PS4) <br>\u2022 DF control board (DFCB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<h2 class=\"wp-block-heading\">Procedure<\/h2>\n\n\n\n<p>When&nbsp;DF-632&nbsp;is installed<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M5-DFCB J18 for proper connection and correct as necessary.<\/li><li>Check the connector of M5 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS11-DFCB J18 for proper connection and correct as necessary.<\/li><li>PS11 I\/O check, sensor check<ul><li>Control signal: DFCB J18-3 (ON)<\/li><li>Location of electrical component:\u00a0DF-632\u00a01-G<\/li><\/ul><\/li><li>M5 load check<ul><li>Check code: 60<\/li><li>Multi code: 81, 82<\/li><li>Control signal: DFCB J18-4 to 5<\/li><li>Location of electrical component:\u00a0DF-632\u00a02-G<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6224515723.html\">Replace M5<\/a>. (Part# A3CFPP6J00)<\/li><li>DFCB F8 conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6224465803.html\">Replace DFCB<\/a>. (Part# AAYHPP0200)<\/li><\/ol>\n\n\n\n<p>When&nbsp;DF-714&nbsp;is installed<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Check the connector between M4-DFCB J18 for proper connection and correct as necessary.<\/li><li>Check the connector of M4 for proper drive coupling and correct as necessary.<\/li><li>Check the connector between PS4-DFCB J18 for proper connection and correct as necessary.<\/li><li>PS4 I\/O check, sensor check<ul><li>Control signal: DFCB J18-3 (ON)<\/li><li>Location of electrical component:\u00a0DF-714\u00a01-G<\/li><\/ul><\/li><li>M4 load check<ul><li>Check code: 60<\/li><li>Multi code: 81, 82<\/li><li>Control signal: DFCB J18-4 to 5<\/li><li>Location of electrical component:\u00a0DF-714\u00a01-G<\/li><\/ul><\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6224669579.html\">Replace M4<\/a>. (Part# A3CEPP5700)<\/li><li>DFCB F8 conduction check<\/li><li><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6224606859.html\">Replace DFCB<\/a>. (Part# AAYHPP0200) <\/li><\/ol>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhubC360iService\/en-US\/6376392459.html\">L.3.14.1<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type C8101: Before reading pressure welding alienation mechanism (When&nbsp;DF-632&nbsp;or&nbsp;DF-714&nbsp;is installed) Rank B Trouble detection condition &lt;When&nbsp;DF-632&nbsp;is installed&gt;\u2022 During a pressure motion being performed, the reading roll position sensor (PS11) output does not change from H to L. \u2022 During a retraction motion being performed, the reading roll position sensor (PS11) output does not &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c8101-bizhub-c360i-c300i-c250i\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C8101 (bizhub C360i\/C300i\/C250i)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[943],"epkb_post_type_1_tag":[],"class_list":["post-764","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c8-c360i-c300i-c250i-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=764"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/764\/revisions"}],"predecessor-version":[{"id":8893,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/764\/revisions\/8893"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=764"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=764"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=764"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}