{"id":8532,"date":"2019-06-26T18:44:34","date_gmt":"2019-06-26T18:44:34","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=8532"},"modified":"2023-12-21T15:33:46","modified_gmt":"2023-12-21T15:33:46","slug":"cd201-bizhub-364e-284e-224e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd201-bizhub-364e-284e-224e","title":{"rendered":"CD201 (bizhub 364e\/284e\/224e)"},"content":{"rendered":"\n<p>Contents <\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>\nTrouble type<\/td><td>\nFile memory mounting error<\/td><\/tr><tr><td>\nTrouble code<\/td><td>\nCD201<\/td><\/tr><tr><td>\nRank<\/td><td>\nC<\/td><\/tr><tr><td>\nDetection timing<\/td><td> \u2022 The file memory is not  mounted.  <br> \u2022 The file has any  abnormality. <\/td><\/tr><tr><td>\nTrouble isolation<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\nRelevant electrical parts<\/td><td> \u2022 MFP board (MFPB)  <br> \u2022 Memory board\/1 (MEMB\/1)  <br> \u2022 Memory board\/2 (MEMB\/2;  UK-204) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n&nbsp;\n(2)Procedure\n\n\n\n\n<\/p>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><td>\nStep<\/td><td>\nAction<\/td><td>\nControl signal<\/td><td>\nLocation of electrical \ncomponents<\/td><\/tr><\/thead><tbody><tr><td>\n1<\/td><td>\nCheck to see if MEMB\/1 or MEMB\/2 on MFPB is \ninstalled correctly.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n2<\/td><td> Replace MEMB\/1 or MEMB\/2 on MFPB. (Part# V865300066 )#<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n3<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001125623\/D0001125623.html\">Replace MFPB.<\/a>MFPB (Part# A61FH02005)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li> Link to the layout drawings for related parts by  each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001199051\/D0001199051.html\">S.86.  CD201, CD202, CD203<\/a>)<\/li><\/ul>\n\n\n\n<p>\n\n\n\nDocument Information\n\n\nID\nD0001128003\nRevise ID\nR000003<\/p>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001128003\/D0001128003.html\">K.3.16.10<\/a>  (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type File memory mounting error Trouble code CD201 Rank C Detection timing \u2022 The file memory is not mounted. \u2022 The file has any abnormality. Trouble isolation &#8211; Relevant electrical parts \u2022 MFP board (MFPB) \u2022 Memory board\/1 (MEMB\/1) \u2022 Memory board\/2 (MEMB\/2; UK-204) &nbsp; (2)Procedure Step Action Control signal Location of electrical &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=cd201-bizhub-364e-284e-224e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;CD201 (bizhub 364e\/284e\/224e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[758],"epkb_post_type_1_tag":[],"class_list":["post-8532","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-cd-364e-284e-224e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/8532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8532"}],"version-history":[{"count":5,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/8532\/revisions"}],"predecessor-version":[{"id":12548,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/8532\/revisions\/12548"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8532"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=8532"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=8532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}