{"id":9441,"date":"2019-07-02T17:27:35","date_gmt":"2019-07-02T17:27:35","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=9441"},"modified":"2023-12-21T15:29:18","modified_gmt":"2023-12-21T15:29:18","slug":"c1109-bizhub-364e-284e-224e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1109-bizhub-364e-284e-224e","title":{"rendered":"C1109  (bizhub 364e\/284e\/224e)"},"content":{"rendered":"\n<p>\n\nContents<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>Trouble type<\/td><td>Stapler motor&#8217;s drive malfunction<\/td><\/tr><tr><td>Trouble code<\/td><td>C1109<\/td><\/tr><tr><td>Rank<\/td><td>B<\/td><\/tr><tr><td>Detection timing<\/td><td>&lt;When FS-533 is installed&gt; <br>The stapler home sensor (PS110) is not blocked even after the set period of time has elapsed after the stapler motor turned ON. <\/td><td><\/td><\/tr><tr><td><\/td><td> &lt;When FS-534 is installed&gt; <br>\u2022 The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the stapler motor (M14) turned ON. <br>\u2022  The stapler position sensor (Center) (PS24) is blocked, when the stapler motor (M14) is running.<\/td><\/tr><tr><td>Trouble isolation<\/td><td>Staple<\/td><\/tr><tr><td>Relevant electrical parts<\/td><td>&lt;When FS-533 is installed&gt; <br> \u2022  Stapler home sensor (PS110) <br>\u2022  Stapler unit <br>\u2022  Stapler relay board (STREYB) <br>\u2022  FS control board (FSCB) <\/td><td><\/td><\/tr><tr><td><\/td><td> &lt;When FS-534 is installed&gt; <br> \u2022  Stapler home position sensor (Rear) (PS23) <br>\u2022  Stapler unit <br>\u2022  Stapler position sensor (Center) (PS24) <br>\u2022  FS control board (FSCB)<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>&nbsp;(2)ProcedureWhen FS-533 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between the stapler unit-STREYB CN122 and CN123 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of the stapler unit for proper drive coupling and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>PS110 I\/O check, sensor check<\/td><td>FSCB CN110<\/td><td>FS-533 8-D to E<\/td><\/tr><tr><td>5<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001125920\/D0001125920.html\">Replace the stapler unit<\/a> (Part# A2YUPPK401 )<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>6<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001125924\/D0001125924.html\">Replace STREYB<\/a>  (Part# A2YUPPG700 ) <\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001125923\/D0001125923.html\">Replace FSCB<\/a> FS-533 (Part# A2YUPPH901 for Model No. A2YU-WY1 or Part # A2YUPPXN00 for Model No. A2YU-WY2)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001128481\/D0001128481.html\">N.2.6 FS-533<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001198971\/D0001198971.html#sct_1\">S.19.1 FS-533<\/a>)<\/li><\/ul>\n\n\n\n<p>When FS-534 is installed<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><thead><tr><td>Step<\/td><td>Action<\/td><td>Control signal<\/td><td>Location of electrical components<\/td><\/tr><\/thead><tbody><tr><td>1<\/td><td>Check the connector between the stapler unit-relay CN4-FSCB J11 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>2<\/td><td>Check the connector of the stapler unit for proper drive coupling, and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>3<\/td><td>Check the connector between PS23-relay CN3-FSCB J11 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>4<\/td><td>Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary.<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>5<\/td><td>PS23 I\/O check, sensor check<\/td><td>FSCB J11&lt;B&gt;-3 (ON)<\/td><td>FS-534 4-C<\/td><\/tr><tr><td>6<\/td><td>PS24 I\/O check, sensor check<\/td><td>FSCB J11&lt;B&gt;-6 (ON)<\/td><td>FS-534 4 to 5-C<\/td><\/tr><tr><td>7<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001125856\/D0001125856.html\">Replace the stapler unit<\/a> (Part# A3EP560100 )<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>8<\/td><td><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001125859\/D0001125859.html\">Replace FSCB<\/a> (Part# A3EPPPBE01)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li>Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001128482\/D0001128482.html\">N.2.7 FS-534<\/a>)<\/li><li>Link to the layout drawings for related parts by each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001198971\/D0001198971.html#sct_2\">S.19.2 FS-534<\/a>)<\/li><\/ul>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p>(Link to the Field Service Manual)  <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub364eService\/D0001127801\/D0001127801.html\">K.3.6.7<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type Stapler motor&#8217;s drive malfunction Trouble code C1109 Rank B Detection timing &lt;When FS-533 is installed&gt; The stapler home sensor (PS110) is not blocked even after the set period of time has elapsed after the stapler motor turned ON. &lt;When FS-534 is installed&gt; \u2022 The stapler home position sensor (Rear) (PS23) is not &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c1109-bizhub-364e-284e-224e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C1109  (bizhub 364e\/284e\/224e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[747],"epkb_post_type_1_tag":[],"class_list":["post-9441","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c1-364e-284e-224e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/9441","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=9441"}],"version-history":[{"count":4,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/9441\/revisions"}],"predecessor-version":[{"id":13678,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/9441\/revisions\/13678"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=9441"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=9441"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=9441"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}