{"id":9870,"date":"2019-07-03T19:05:01","date_gmt":"2019-07-03T19:05:01","guid":{"rendered":"http:\/\/localhost\/bizhubtroubleshooter\/?post_type=epkb_post_type_1&#038;p=9870"},"modified":"2023-12-21T15:25:12","modified_gmt":"2023-12-21T15:25:12","slug":"c0216-bizhub-554e-454e","status":"publish","type":"epkb_post_type_1","link":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0216-bizhub-554e-454e","title":{"rendered":"C0216 (bizhub 554e\/454e)"},"content":{"rendered":"\n<p>Contents <\/p>\n\n\n\n<table class=\"wp-block-table\"><tbody><tr><td>\nTrouble type<\/td><td>\nLCT up\/down abnormality<\/td><\/tr><tr><td>\nTrouble code<\/td><td>\nC0216<\/td><\/tr><tr><td>\nRank<\/td><td>\nB<\/td><\/tr><tr><td>\nDetection timing<\/td><td>\nThe upper limit sensor (PS2) is not blocked even \nafter the set period of time has elapsed after the paper lift-up operation \nbegan.<\/td><\/tr><tr><td>\nTrouble isolation<\/td><td>\nLCT<\/td><\/tr><tr><td>\nRelevant electrical parts<\/td><td> \u2022 Upper limit sensor (PS2)  <br> \u2022 Lift-up motor (M1)  <br> \u2022 LU drive board  (LUDB) <\/td><\/tr><\/tbody><\/table>\n\n\n\n<p>\n&nbsp;\n(2)Procedure\n\n\nWhen LU-204 is installed\n\n\n<\/p>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><td>\nStep<\/td><td>\nAction<\/td><td>\nControl signal<\/td><td>\nLocation of electrical \ncomponents<\/td><\/tr><\/thead><tbody><tr><td>\n1<\/td><td>\nCheck the connector between M1-LCDB CN3 for proper \nconnection, and correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n2<\/td><td>\nCheck the connector of M1 for proper drive coupling \nand correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n3<\/td><td>\nCheck the connectors between PS2-relay CN406-LCDB \nCN5 for proper connection, and correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n4<\/td><td>\nPS2 I\/O check, sensor check<\/td><td>\nLUDB CN5-3 (ON)<\/td><td>\nLU-204 4-G<\/td><\/tr><tr><td>\n5<\/td><td>\nM1 operation check<\/td><td>\nLUDB CN3-4 (ON)<\/td><td>\nLU-204 3-G<\/td><\/tr><tr><td>\n6<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131836\/D0001131836.html\">Replace M1<\/a>M1 (Part# A3CEPP4C00)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n7<\/td><td>\nLUDB ICP2 conduction check<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n8<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131834\/D0001131834.html\">Replace LUDB<\/a>LUDB:<br> LU-302 (Part# A87VH01000)<br> LU-207 (Part# A87VH01000)<br> LU-303 (Part# A8H6H00100)<br> LU-205 (Part# A8H6H00100)<br> LU-204 (Part# A0TJH00100)<br> LU-301 (Part# A03NH00101)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li> Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001135340\/D0001135340.html\">N.3.4  LU-204<\/a>)<\/li><li> Link to the layout drawings for related parts by  each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001199199\/D0001199199.html\">S.13.  C0216<\/a>)<\/li><\/ul>\n\n\n\n<p>\n\n\nWhen LU-301 is installed\n\n\n<\/p>\n\n\n\n<table class=\"wp-block-table\"><thead><tr><td>\nStep<\/td><td>\nAction<\/td><td>\nControl signal<\/td><td>\nLocation of electrical \ncomponents<\/td><\/tr><\/thead><tbody><tr><td>\n1<\/td><td>\nCheck the connector between M1-LCDB CN3 for proper \nconnection, and correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n2<\/td><td>\nCheck the connector of M1 for proper drive coupling \nand correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n3<\/td><td>\nCheck the connectors between PS2-relay CN3-LCDB CN5 \nfor proper connection, and correct as necessary.<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n4<\/td><td>\nPS2 I\/O check, sensor check<\/td><td>\nLUDB CN5-3 (ON)<\/td><td>\nLU-301 4-G<\/td><\/tr><tr><td>\n5<\/td><td>\nM1 operation check<\/td><td>\nLUDB CN3-4 (ON)<\/td><td>\nLU-301 3-G<\/td><\/tr><tr><td>\n6<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131861\/D0001131861.html\">Replace M1<\/a>M1 (Part# A3CEPP4C00)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n7<\/td><td>\nLUDB ICP2 conduction check<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><tr><td>\n8<\/td><td> <a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001131859\/D0001131859.html\">Replace LUDB<\/a>LUDB:<br> LU-302 (Part# A87VH01000)<br> LU-207 (Part# A87VH01000)<br> LU-303 (Part# A8H6H00100)<br> LU-205 (Part# A8H6H00100)<br> LU-204 (Part# A0TJH00100)<br> LU-301 (Part# A03NH00101)<\/td><td>\n&#8211;<\/td><td>\n&#8211;<\/td><\/tr><\/tbody><\/table>\n\n\n\n<ul class=\"wp-block-list\"><li> Link to the wiring diagram (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001135344\/D0001135344.html\">N.3.5  LU-301<\/a>)<\/li><li> Link to the layout drawings for related parts by  each trouble code (<a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001199199\/D0001199199.html\">S.13.  C0216<\/a>)<\/li><\/ul>\n\n\n\n<p>\n\n\n\nDocument Information\n\n\nID\nD0001134251\nRevise ID\nR000003<\/p>\n\n\n\n<p><strong>Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.<\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/wapps.mykonicaminolta.com\/msman\/m\/service\/bizhub454eService\/D0001134251\/D0001134251.html\">K.3.5.13<\/a> (Link to the Field Service Manual)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contents Trouble type LCT up\/down abnormality Trouble code C0216 Rank B Detection timing The upper limit sensor (PS2) is not blocked even after the set period of time has elapsed after the paper lift-up operation began. Trouble isolation LCT Relevant electrical parts \u2022 Upper limit sensor (PS2) \u2022 Lift-up motor (M1) \u2022 LU drive board &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/?epkb_post_type_1=c0216-bizhub-554e-454e\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;C0216 (bizhub 554e\/454e)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":231,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"epkb_post_type_1_category":[920],"epkb_post_type_1_tag":[],"class_list":["post-9870","epkb_post_type_1","type-epkb_post_type_1","status-publish","hentry","epkb_post_type_1_category-c0-554e-454e-trouble-code"],"_links":{"self":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/9870","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1"}],"about":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/types\/epkb_post_type_1"}],"author":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/users\/231"}],"replies":[{"embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=9870"}],"version-history":[{"count":3,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/9870\/revisions"}],"predecessor-version":[{"id":11448,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=\/wp\/v2\/epkb_post_type_1\/9870\/revisions\/11448"}],"wp:attachment":[{"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=9870"}],"wp:term":[{"taxonomy":"epkb_post_type_1_category","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_category&post=9870"},{"taxonomy":"epkb_post_type_1_tag","embeddable":true,"href":"https:\/\/apps.kmbizhubvcare.com\/bizhubtroubleshooter\/index.php?rest_route=%2Fwp%2Fv2%2Fepkb_post_type_1_tag&post=9870"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}