How Can We Help?

17-40, 17-41 (bizhub 950i/850i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at tray 3/4 intermediate transport roller section
JAM code17-40, 17-41
JAM detection timing17-40LCC vertical transport sensor (PS28) is not turned ON even after the lapse of a given period of time after the leading edge of the paper has turned ON the tray 4 paper feed sensor (PS26).
17-41The tray 2 vertical transport sensor (PS12) is not turned ON even after the lapse of a given period of time after the leading edge of the paper has turned ON the LCC vertical transport sensor (PS28).
Paper jam of a sheet of paper left at the tray 3/4 intermediate transport roller section results, if the tray LCC vertical transport sensor (PS28) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Paper jam of a sheet of paper left at the tray 3/4 intermediate transport roller section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing location-Right bottom door
-Tray 3/4 horizontal transport unit
Relevant parts-LCC vertical transport motor (M26)
-LCC transport motor (M25)
-Tray 2 vertical transport motor (M7)
-Tray 4 paper feed clutch (CL7)
-LCC Vertical transport sensor (PS28)
-Tray 4 paper feed sensor (PS26)
-Tray 2 vertical transport sensor (PS12)
-Paper feed/transport drive board (PFTDB)
-Base board (BASEB)

Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS28 I/O check, sensor checkPFTDB CN15-15 (ON)10-X
3PS26 I/O check, sensor checkPFTDB CN19-3 (ON)7-X
4PS12 I/O check, sensor checkPFTDB CN12-10 (ON)1-P
5CL7 load check

-Check code: 20

-Multi code: 4
PFTDB CN18-2 (REM)7-X
6M26 load check

-Check code: 28

-Multi code: 29, 30, 31, 32
PFTDB CN11-1 to 410-X
7M25 load check

-Check code: 28

-Multi code: 25, 26, 27, 28
PFTDB CN13-1 to 711-X
8M7 load check

-Check code: 28

-Multi code: 13, 14, 15, 16
PFTDB CN10-9 to 1218-P
9PFTDB F21, F23, F24, or F27 conduction check.
10Replace PFTDB.
11Replace BASEB.

(Link to the Field Service Manual)

Table of Contents