How Can We Help?

30-03 (bizhub 950i/850i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeMisfeed at 2nd transfer section
JAM code30-03
JAM detection timing30-03The paper exit sensor (PS39), fusing loop sensor /Fr (PS41), or when the fusing loop sensor/Rr (PS42) is not turned ON even after the lapse of a given period of time after the leading edge of the paper has turned ON the registration sensor (PS38).
Paper jam of a sheet of paper left at the 2nd transfer section results, if the registration sensor (PS38) is turned ON when the main power switch ON turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Paper jam of a sheet of paper left at the 2nd transfer section results, if the main power switch is turned ON, the registration sensor (PS38) or the paper exit sensor (PS39) is turned ON.
Paper jam of a sheet of paper left at the 2nd transfer section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationRight door
Relevant parts-Registration motor (M2)
-Fusing motor (M30)
-Registration sensor (PS38)
-Fusing loop sensor/Fr (PS41)
-Fusing loop sensor/Rr (PS42)
-Paper exit sensor (PS39)
-Paper feed/transport drive board (PFTDB)
-Base board (BASEB)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS38 I/O check, sensor checkPFTDB CN2-5 (ON)8-P
3PS41 I/O check, sensor checkPFTDB CN5-3 (ON)6-P
4PS42 I/O check, sensor checkPFTDB CN5-6 (ON)6-P
5PS39 I/O check, sensor checkPFTDB CN2-12 (ON)8-P
6M2 load check

-Check code: 26

-Multi code: 1, 2, 3, 4
PFTDB CN7-1 to 45-P
7M30 load check

-Check code: 45

-Multi code: 1, 2, 3, 4, 5, 6
BASEB CN16E-1 to 78-K
8PFTDB F28 conduction check.
9Replace PFTDB.
10BASEB F13E conduction check.
11Replace BASEB.

(Link to the Field Service Manual)