How Can We Help?

66-02 (bizhub 558/458)

You are here:

Contents

JAM typeMisfeed at DF paper feed section
JAM code66-02
JAM detection timingThe after separate sensor (PS2) is not turned ON (blocked) after a lapse of a given time after the document feed motor (M2) is turned ON.
Misfeed processing locationLeft cover
Relevant parts• Document feed motor (M2)
• After separate sensor (PS2)
• Document length size sensor 1 (PS8)
• Document length size sensor 2 (PS9)
• Document width size sensor (VR1)
• DF control board (DFCB)

 Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2Make the adjusting the pressure of the separation roller.
3PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-704 6-G
4PS8 I/O check, sensor checkDFCB J12-6 (ON)DF-704 3 to 4-G
5PS9 I/O check, sensor checkDFCB J12-5 (ON)DF-704 3-G
6VR1 I/O check, sensor checkDFCB J12-3 (ON)DF-704 4-G
7M2 operation checkDFCB J5-1 to 4DF-704 1 to 2-B
8Replace DFCB. (Part# A85GPP0M00)
  • Link to the wiring diagram (DF-704)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.15.1 (Link to the Field Service Manual)