JAM typeMisfeed at DF paper feed section
JAM code66-02
JAM detection timing<When DF-629 or DF-704 is installed>
The after separate sensor (PS2) is not turned ON (blocked) after a lapse of a given time after the document feed motor (M2) is turned ON.
Misfeed processing locationLeft cover
Relevant parts<When DF-629 is installed>
• Document feed motor (M2)
• After separate sensor (PS2)
• Document length size sensor/1 (PS6)
• Document length size sensor/2 (PS7)
• Document width size sensor (VR1)
• DF control board (DFCB)
<When DF-704 is installed>
• Document feed motor (M2)
• After separate sensor (PS2)
• Document length sensor/1 (PS8)
• Document length sensor/2 (PS9)
• Document width sensor (VR1)
• DF control board (DFCB)

 Procedure

 When DF-629 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-629 6-G
3PS6 I/O check, sensor checkDFCB J12-6 (ON)DF-629 4-G
4PS7 I/O check, sensor checkDFCB J12-5 (ON)DF-629 4-G
5VR1 I/O check, sensor checkDFCB J12-3 (ON)DF-629 4-G
6M2 operation checkDFCB J5-1 to 4DF-629 2-B
7Replace DFCB. (Part# A87RPP1700)
  • Link to the wiring diagram (DF-629)

 When DF-704 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-704 6-G
3PS8 I/O check, sensor checkDFCB J12-6 (ON)DF-704 3 to 4-G
4PS9 I/O check, sensor checkDFCB J12-5 (ON)DF-704 3-G
5VR1 I/O check, sensor checkDFCB J12-3 (ON)DF-704 4-G
6M2 operation checkDFCB J5-1 to 4DF-704 1 to 2-B
7Replace DFCB. (Part# A85GPP0M00)
  • Link to the wiring diagram (DF-704)