How Can We Help?

66-03 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeDF transport section
JAM code66-03
Detection timing<When DF-624 or DF-701 is installed>
The after separate sensor (PS2) is not unblocked after a lapse of a given time after PS2 is blocked.
Misfeed processing locationLeft cover
Relevant parts<When DF-624 is installed>
-Document reading motor (M1)
-Document feed motor (M2)
-Registration motor (M3)
-After separate sensor (PS2)
-Document registration sensor (PS3)
-Document reading sensor (PS4)
-DF control board (DFCB)
<When DF-701 is installed>
-Document reading motor (M1)
-Document feed motor (M2)
-Registration motor (M3)
-After separate sensor (PS2)
-Registration sensor (PS3)
-Document reading sensor (PS6)
-DF control board (DFCB)

(2)Procedure When DF-624 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-624 6-G
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-624 5-G
4PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-624 2-G
5M1 operation checkDFCB J7-1 to 4DF-624 2-B
6M2 operation checkDFCB J5-1 to 4DF-624 2-B
7M3 operation checkDFCB J6-1 to 4DF-624 3-B
8DFCB F4, F5 conduction check
9Replace DFCB (Part# A3CFPP5Q00)

When DF-701 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkDFCB J14-8 (ON)DF-701 6-G
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-701 4-G
4PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-701 2-G
5M1 operation checkDFCB J7-1 to 4DF-701 1-B
6M2 operation checkDFCB J5-1 to 4DF-701 1 to 2-B
7M3 operation checkDFCB J6-1 to 4DF-701 2-B
8DFCB F4, F5 conduction check
9Replace DFCB (Part# A3CEPP4900)

K1.9.3 (Link to the Field Service Manual)

Table of Contents