JAM typeMisfeed at DF image reading section
JAM code66-05, 66-06, 66-15
JAM detection timing66-05:
<When DF-632 is installed>
The document reading sensor (PS4) is not turned OFF even after the lapse of a given period of time after the document registration sensor (PS3) has turned OFF (blocked).
<When DF-714 is installed>
The document reading sensor (PS6) is not turned OFF even after the lapse of a given period of time after the document registration sensor (PS3) has turned OFF (blocked).
66-06:
<When DF-632 is installed>
The document reading sensor (PS4) is turned ON earlier than a given time after PS4 is turned OFF during original transportation.
<When DF-714 is installed>
The document reading sensor (PS6) is turned ON earlier than a given time after PS6 is turned OFF during original transportation.
66-15:
<When DF-632 is installed>
The document reading sensor (PS4) does not turn OFF even after the lapse of a given period of time after the document registration sensor (PS3) is turned OFF (blocked) after the reverse read operation started.
Paper jam of a sheet of paper left at the DF image reading section results, if the document reading sensor (PS4, PS6) is turned ON when the main power switch is turned ON, a DF left cover is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationLeft cover
Relevant parts<When DF-632 is installed>
-Document reading motor (M1)
-Reading roll release motor (M5)
-Document registration sensor (PS3)
-Document reading sensor (PS4)
-DF control board (DFCB)
<When DF-714 is installed>
-Document reading motor (M1)
-Reading roll release motor (M4)
-Document registration sensor (PS3)
-Document reading sensor (PS6)
-DF control board (DFCB)

Procedure

When DF-632 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2Make the adjustment of original stop position.
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-632 5-G
4PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-632 2-G
5M1 load check
Check code: 60
Multi code: 34, 35, 36, 37, 38, 39
DFCB J7-1 to 4DF-632 2-B
6M5 load check
Check code: 60
Multi code: 81, 82
DFCB J18-4 to 5DF-632 2-G
7Replace DFCB. (Part# AAYHPP0200)

When DF-714 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2Make the adjustment of original stop position.
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-714 4-G
4PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-714 2-G
5M1 load check
Check code: 60
Multi code: 34, 35, 37, 40
DFCB J7-1 to 4DF-714 1-B
6M4 load check
Check code: 60
Multi code: 81, 82
DFCB J18-4 to 5DF-714 1-G
7Replace DFCB. (Part# AAMNPP4901)