66-05 (bizhub 368e/308e)

You are here:

Contents

JAM typeMisfeed at DF image reading section
JAM code66-05
JAM detection timing<When DF-629 is installed>
The document reading sensor (PS4) is not turned OFF after a lapse of a given time after the document registration sensor (PS3) is turned OFF (blocked).
<When DF-704 is installed>
The document reading sensor (PS6) is not turned OFF after a lapse of a given time after the document registration sensor (PS3) is turned OFF (blocked).
Misfeed processing locationLeft cover
Relevant parts<When DF-629 is installed>
• Document reading motor (M1)
• Reading roll release motor (M5)
• Document registration sensor (PS3)
• Document reading sensor (PS4)
• DF control board (DFCB)
<When DF-704 is installed>
• Document reading motor (M1)
• Reading roll release motor (M4)
• Document registration sensor (PS3)
• Document reading sensor (PS6)
• DF control board (DFCB)

 Procedure

 When DF-629 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2Make the adjustment of original stop position.
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-629 5-G
4PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-629 2-G
5M1 load checkCheck code: 60Multi code: 33, 34, 35, 36, 37, 38, 39DFCB J7-1 to 4DF-629 2-B
6M5 load checkCheck code: 60Multi code: 81, 82DFCB J18-4 to 5DF-629 2-G
7Replace DFCB. (Part# A87RPP1700)

 When DF-704 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2Make the adjustment of original stop position.
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-704 4-G
4PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-704 2-G
5M1 load checkCheck code: 60Multi code: 34, 35, 37DFCB J7-1 to 4DF-704 1-B
6M4 load checkCheck code: 60Multi code: 81, 82DFCB J18-4 to 5DF-704 1-G
7Replace DFCB. (Part# A85GPP0M00)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.1.14.5 (Link to the Field Service Manual)