How Can We Help?

66-05 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeDF image reading section
JAM code66-05
Detection timing<When DF-624 is installed>
The document reading sensor (PS4) is not turned OFF after a lapse of a given time after the document registration sensor (PS3) is blocked.
<When DF-701 is installed>
The document reading sensor (PS6) is not turned OFF after a lapse of a given time after the registration sensor (PS3) is blocked.
Misfeed processing locationLeft cover
Relevant parts<When DF-624 is installed>
-Document reading motor (M1)
-Reading roll release motor (M5)
-Document registration sensor (PS3)
-Document reading sensor (PS4)
-DF control board (DFCB)
<When DF-701 is installed>
-Document reading motor (M1)
-Reading roller release motor (M4)
-Registration sensor (PS3)
-Document reading sensor (PS6)
-DF control board (DFCB)

(2)Procedure When DF-624 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2Make the adjustment of original stop position.
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-624 5-G
4PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-624 2-G
5M1 operation checkDFCB J7-1 to 4DF-624 2-B
6M5 operation checkDFCB J18-4 to 5DF-624 2-G
7Replace DFCB (Part# A3CFPP5Q00)

When DF-701 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2Make the adjustment of original stop position.
3PS3 I/O check, sensor checkDFCB J14-12 (ON)DF-701 4-G
4PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-701 2-G
5M1 operation checkDFCB J7-1 to 4DF-701 1-B
6M4 operation checkDFCB J18-4 to 5DF-701 1-G
7Replace DFCB (Part# A3CEPP4900)

K1.9.5 (Link to the Field Service Manual)