66-14 (bizhub 364e/284e/224e)
Contents
| JAM type | DF paper exit section | ||
| JAM code | 66-14 | ||
| Detection timing | <When DF-624 is installed> The document exit sensor (PS5) is not blocked after a lapse of a given time after the document reading sensor (PS4) is turned OFF. | ||
| <When DF-701 is installed> The document exit sensor (PS5) is not blocked after a lapse of a given time after the document reading sensor (PS6) is turned OFF. | |||
| Misfeed processing location | • Left cover • Opening and closing guide | ||
| Relevant parts | <When DF-624 is installed> • Document reading motor (M1) • Document reading sensor (PS4) • Document exit sensor (PS5) • DF control board (DFCB) | ||
| <When DF-701 is installed> • Document reading motor (M1) • Document exit sensor (PS5) • Document reading sensor (PS6) • DF control board (DFCB) |
(2)ProcedureWhen DF-624 is installed
| Step | Action | Control signal | Location of electrical component |
| 1 | Initial check items | – | – |
| 2 | PS4 I/O check, sensor check | DFCB J10-3 (ON) | DF-624 2-G |
| 3 | PS5 I/O check, sensor check | DFCB J15-6 (ON) | DF-624 3-G |
| 4 | M1 operation check | DFCB J7-1 to 4 | DF-624 2-B |
| 5 | Replace DFCB (Part# A3CFPP5Q00) | – | – |
- Link to the wiring diagram (N.2.2 DF-624)
When DF-701 is installed
| Step | Action | Control signal | Location of electrical component |
| 1 | Initial check items | – | – |
| 2 | PS6 I/O check, sensor check | DFCB J10-3 (ON) | DF-701 2-G |
| 3 | PS5 I/O check, sensor check | DFCB J15-6 (ON) | DF-701 3-G |
| 4 | M1 operation check | DFCB J7-1 to 4 | DF-701 1-B |
| 5 | Replace DFCB (Part# A3CEPP4900) | – | – |
- Link to the wiring diagram (N.2.1 DF-701)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.9.4 (Link to the Field Service Manual)