66-14 (bizhub 368/308)

You are here:

Contents

JAM typeMisfeed at DF paper exit section
JAM code66-14
JAM detection timing<When DF-629 is installed> 
The document exit sensor (PS5) is not turned OFF (unblocked) after a lapse of a given time after the document reading sensor (PS4) is turned OFF.
<When DF-704 is installed>
The document exit sensor (PS5) is not turned OFF (unblocked) after a lapse of a given time after the document reading sensor (PS6) is turned OFF.
Misfeed processing location• Left cover 
• Opening and closing guide
Relevant parts<When DF-629 is installed> 
• Document reading motor (M1) 
• Document reading sensor (PS4) 
• Document exit sensor (PS5) 
• DF control board (DFCB)
<When DF-704 is installed>
• Document reading motor (M1) 
• Document exit sensor (PS5) 
• Document reading sensor (PS6) 
• DF control board (DFCB)

 Procedure

 When DF-629 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-629 2-G
3PS5 I/O check, sensor checkDFCB J15-6 (ON)DF-629 3-G
4M1 operation checkDFCB J7-1 to 4DF-629 2-B
5Replace DFCB. (Part# A87RPP1700)
  • Link to the wiring diagram (DF-629)

 When DF-704 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-704 2-G
3PS5 I/O check, sensor checkDFCB J15-6 (ON)DF-704 3-G
4M1 operation checkDFCB J7-1 to 4DF-704 1-B
5Replace DFCB. (Part# A85GPP0M00)
  • Link to the wiring diagram (DF-704)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.