How Can We Help?

66-14 (bizhub C364/C284/C224)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

JAM typeDF paper exit section
JAM code66-14
Detection timing<When DF-624 is installed>
The document exit sensor (PS5) is not blocked after a lapse of a given time after the document reading sensor (PS4) is turned OFF.
<When DF-701 is installed>
The document exit sensor (PS5) is not blocked after a lapse of a given time after the document reading sensor (PS6) is turned OFF.
Misfeed processing location-Left cover
-Opening and closing guide
Relevant parts<When DF-624 is installed>
-Document reading motor (M1)
-Document reading sensor (PS4)
-Document exit sensor (PS5)
-DF control board (DFCB)
<When DF-701 is installed>
-Document reading motor (M1)
-Document exit sensor (PS5)
-Document reading sensor (PS6)
-DF control board (DFCB)

(2)Procedure When DF-624 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS4 I/O check, sensor checkDFCB J10-3 (ON)DF-624 2-G
3PS5 I/O check, sensor checkDFCB J15-6 (ON)DF-624 3-G
4M1 operation checkDFCB J7-1 to 4DF-624 2-B
6Replace DFCB (Part# A3CFPP5Q00)

When DF-701 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS6 I/O check, sensor checkDFCB J10-3 (ON)DF-701 2-G
3PS5 I/O check, sensor checkDFCB J15-6 (ON)DF-701 3-G
4M1 operation checkDFCB J7-1 to 4DF-701 1-B
6Replace DFCB (Part# A3CEPP4900)

K1.9.4 (Link to the Field Service Manual)

Table of Contents