66-33 (bizhub C364e/C284e/C224e)
Contents
| JAM type | DF transport section | |
| JAM code | 66-33 | |
| Detection timing | <When DF-624 is installed>  The document reading sensor (PS4) is not blocked after a lapse of a given time after the document registration sensor (PS3) is unblocked.  | |
| <When DF-701 is installed> The document reading sensor (PS6) is not blocked after a lapse of a given time after the registration sensor (PS3) is unblocked.  | ||
| Misfeed processing location | Left cover | |
| Relevant parts | <When DF-624 is installed> -Document reading motor (M1) -Document feed motor (M2) -Registration motor (M3) -After separate sensor (PS2) -Document registration sensor (PS3) -Document reading sensor (PS4) -DF control board (DFCB)  | |
| <When DF-701 is installed> -Document reading motor (M1) -Document feed motor (M2) -Registration motor (M3) -After separate sensor (PS2) -Registration sensor (PS3) -Document reading sensor (PS6) -DF control board (DFCB)  | 
(2)ProcedureWhen DF-624 is installed
| Step | Action | Control signal | Location of electrical component | 
| 1 | Initial check items | – | – | 
| 2 | PS2 I/O check, sensor check | DFCB J14-8 (ON) | DF-624 6-G | 
| 3 | PS3 I/O check, sensor check | DFCB J14-12 (ON) | DF-624 5-G | 
| 4 | PS4 I/O check, sensor check | DFCB J10-3 (ON) | DF-624 2-G | 
| 5 | M1 operation check | DFCB J7-1 to 4 | DF-624 2-B | 
| 6 | M2 operation check | DFCB J5-1 to 4 | DF-624 2-B | 
| 7 | M3 operation check | DFCB J6-1 to 4 | DF-624 3-B | 
| 8 | DFCB F4, F5 conduction check | – | – | 
| 9 | Replace DFCB (Part# A3CFPP5Q00) | – | – | 
- Link to the wiring diagram (N.2.2 DF-624)
 
When DF-701 is installed
| Step | Action | Control signal | Location of electrical component | 
| 1 | Initial check items | – | – | 
| 2 | PS2 I/O check, sensor check | DFCB J14-8 (ON) | DF-701 6-G | 
| 3 | PS3 I/O check, sensor check | DFCB J14-12 (ON) | DF-701 4-G | 
| 4 | PS6 I/O check, sensor check | DFCB J10-3 (ON) | DF-701 2-G | 
| 5 | M1 operation check | DFCB J7-1 to 4 | DF-701 1-B | 
| 6 | M2 operation check | DFCB J5-1 to 4 | DF-701 1 to 2-B | 
| 7 | M3 operation check | DFCB J6-1 to 4 | DF-701 2-B | 
| 8 | DFCB F4, F5 conduction check | – | – | 
| 9 | Replace DFCB (Part# A3CEPP4900) | – | – | 
- Link to the wiring diagram (N.2.1 DF-701)
 
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.9.3 (Link to the Field Service Manual)