72-16 (bizhub 754e/654e)
Contents
JAM type | FS transport section | ||
JAM code | 72-16 | ||
Detection timing | <When FS-534 is installed> The FNS entrance sensor (PS4) is not turned ON even after the set period of time has elapsed after the RU entrance sensor (PS2) is blocked by the paper. | ||
<When FS-535 is installed> The FNS entrance sensor (PS1) is not turned ON even after the set period of time has elapsed after the RU transport sensor (PS60) is blocked by the paper. | |||
Misfeed processing location | Horizontal conveyance cover | ||
Relevant parts | <When FS-534 is installed> • RU entrance sensor (PS2) • FNS entrance sensor (PS4) • FS control board (FSCB) | ||
<When FS-535 is installed> • RU transport sensor (PS60) • FNS entrance sensor (PS1) • FS control board (FSCB) |
(2)ProcedureWhen FS-534 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS2 I/O check, sensor check | FSCB J6-7 (ON) | FS-534 6-K |
3 | PS4 I/O check, sensor check | FSCB J7-13 (ON) | FS-534 8-K |
4 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.4 Finisher FS-534)
When FS-535 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS60 I/O check, sensor check | RUCB CN206-3 (ON) | FS-535 3-P to Q |
3 | PS1 I/O check, sensor check | FSCB CN2-8 (ON) | FS-535 1-J to K |
4 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.2.7 Finisher FS-535)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.6 (Link to the Field Service Manual)