72-18 (bizhub 364e/284e/224e)
Contents
JAM type | FS transport section | ||
JAM code | 72-18 | ||
Detection timing | <When FS-534 is installed> • The saddle exit sensor (PS5) is not turned ON even after the set period of time has elapsed after the FNS entrance sensor (PS4) is turned ON by the paper. • While the buffer is controlled, the saddle exit sensor (PS5) is not tuned ON even after the set period of time has elapsed after the reverse rotation drive is started. | ||
Misfeed processing location | Front door | ||
Relevant parts | • FNS entrance sensor (PS4) • Saddle exit sensor (PS5) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS4 I/O check, sensor check | FSCB J7-13 (ON) | FS-534 8-K |
3 | PS5 I/O check, sensor check | FSCB J5-2 (ON) | FS-534 10-K |
4 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.7 FS-534)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.5 (Link to the Field Service Manual)