72-18 (bizhub C364e/C284e/C224e)
Contents
JAM type | FS transport section | ||
JAM code | 72-18 | ||
Detection timing | <When FS-534 is installed> The saddle exit sensor (PS5) is not turned ON even after the set period of time has elapsed after the FNS entrance sensor (PS4) is turned ON by the paper.While the buffer is controlled, the saddle exit sensor (PS5) is not tuned ON even after the set period of time has elapsed after the reverse rotation drive is started. | ||
Misfeed processing location | Front door | ||
Relevant parts | -FNS entrance sensor (PS4) -Saddle exit sensor (PS5) -FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS4 I/O check, sensor check | FSCB J7-13 (ON) | FS-534 8-K |
3 | PS5 I/O check, sensor check | FSCB J5-2 (ON) | FS-534 10-K |
4 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.7 FS-534)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.5 (Link to the Field Service Manual)