When FS-539 or FS-539SD is installed

Contents

JAM typeMisfeed at FS transport section (When FS-539 or FS-539SD is installed)
JAM code72-19
JAM detection timingThe main tray exit sensor (PS16) is not turned OFF even after the lapse of a given period of time after the leading edge of the paper has turned ON PS16.
Misfeed processing locationFront door
Relevant parts-FNS discharge motor (M3)
-Main tray exit sensor (PS16)
-FS control board (FSCB)

Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS16 I/O check, sensor checkFSCB J9<B>-5 (ON)FS-539/FS-539SD 11-C
3M3 operation checkFSCB J9<A>-5 to 8FS-539/FS-539SD 12-C
4Replace FSCB. (Part# AAR4PP8201)

(Link to the Field Service Manual)