72-19 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | FS transport section | ||
JAM code | 72-19 | ||
Detection timing | <When FS-534 is installed> The saddle exit sensor (PS5) is not turn OFF even after the set period of time has elapsed after it turns ON. | ||
Misfeed processing location | Front door | ||
Relevant parts | -Saddle exit sensor (PS5) -FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS5 I/O check, sensor check | FSCB J5-2 (ON) | FS-534 10-K |
3 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.7 FS-534)
K1.10.6 (Link to the Field Service Manual)