JAM typeFS transport section
JAM code72-19
Detection timing<When FS-534 is installed>
The saddle exit sensor (PS5) is not turn OFF even after the set period of time has elapsed after it turns ON.
<When FS-535 is installed>
The stacker entrance sensor (PS3) is not turn OFF even after the set period of time has elapsed after it turns ON.
Misfeed processing locationFront door
Relevant parts<When FS-534 is installed>
-Saddle exit sensor (PS5)
-FS control board (FSCB)
<When FS-535 is installed>
-Stacker entrance sensor (PS3)
-FS control board (FSCB)

(2)Procedure When FS-534 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS5 I/O check, sensor checkFSCB J5-2 (ON)FS-534 10-K
3Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS3 I/O check, sensor checkFSCB CN21-5 (ON)FS-535 7-L
3Replace FSCB (Part# A2Y1H10002)